STEP 1  Follow steps 1, 2, 3 and 4 of the "STANDARD SASH WINDOW 
INSTALLATION" instructions beginning on page 10.
STEP 2  CABINET PREPARATION – Remove the sill plate from the 
cabinet by removing the two nuts and screws re tain ing the sill 
plate. Note that the chassis retainer is secured by a right side 
nut and screw (See Detail 1, Figure A.) Bend the tabs of the 
sill plate down into its channel at both ends of the plate or cut 
them off (See Detail 2, Figure A.) Turn the sill plate end to end, 
180° and reinstall. Reverse the ori en ta tion of nuts and screws 
so that the head of screw is on bottom of cabinet facing up and 
nut is on top facing down (See Detail 3, Figure A.) Insure that 
the chassis retainer is reinstalled as shown in the detail.
Figure A
BEFORE
AFTER
CABINET
SILL 
PLATE
TURN SILL PLATE 
END TO END
SCREW
(2 REQUIRED)
NOTE: HOLES 
MOVED TO 
BACK SIDE
NUT 
(2 REQUIRED)
RETAINER, CHASSIS 
THIS SIDE ONLY
DETAIL 1
BEND TABS DOWN
DETAIL 2
DETAIL 3
SCREW
(2 REQUIRED)
SCREW AND NUT 
ORIENTATION NOW 
REVERSED
NUT
(2 REQUIRED)
STEP 3  WALL PREPARATION – The maximum wall thickness permis-
sible without special construction is de ter mined by the model size 
to be installed. THE OUTSIDE CABINET CONDENSER-AIR-
INTAKE-LOU VERS MUST NOT BE BLOCKED BY EXTENDING 
INSIDE THE WALL AREA. Observe the maximum wall thickness 
shown in the chart and di a gram in Figure B.
 
SPECIAL INSTRUCTIONS FOR EXTRA THICK WALLS – 
For installation in walls exceeding the max i mum thickness shown 
in the chart, the following suggested construction may apply.
2" MINIMUM
BOTH SIDES
CONDENSER AIR
INTAKE LOUVERS
MAXIMUM WALL THICKNESS
CONDENSER
AIR INTAKE
LOUVERS
TOP VIEW SHOW ING 
BEVELED SIDES FOR 
AIR INTAKE. WALL 
BELOW UNIT MUST BE 
BEVELED ALSO.
TOP VIEW
CONDITIONED ROOM SIDE AIR
CONDENSER AIR 
OUTLET / REJECTED 
HEATED AIR
NOTE: Condenser air inlets 
and outlet must be unobstruct-
ed to avoid the recirculation of 
rejected heated air.
MODEL
A
SMALL CHASSIS
7 ⅜"
MEDIUM CHASSIS
7 ⅜"
LARGE CHASSIS
15 ⅛"
Through-the-wall Installations
The following instructions apply to wood, masonry, brick, concrete or cinder block wall con struc tion
Figure B    EXTRA THICK WALL CON STRUC TION