Bryan Boilers AB120-W-FDGO ユーザーズマニュアル

ページ / 4
Low initial cost, high  operating effi ciency
deliver substantial return on investment
Quality Construction Features:
 True “fl exible water tube” 
design guaranteed shock free
 Longer lasting with better
performance
 Full fi ve sq ft of heating 
surface per BHP
C
K. Bryan bent water tubes 
are fl exible, individually 
replaceable without welding 
or rolling. Never more than 
two tube confi gurations. 
L. Pressurized design 
fi rebox with internal water-
cooled furnace with low 
heat release rate.
M. Steam boilers with extra 
large drum with high steam 
release area ensure stable 
water level and dry steam.
A. Water side  
or steam side interior ac 
cessible for 
clean out and inspection, front and rear open 
ings, 
upper and lower drums.
B. Large volume water leg down 
comers promote 
rapid internal circulation, temperature equalization and 
effi cient heat transfer.
C.  Boiler tube and furnace area access panels: heavy 
gauge steel casing with 2" high-temperature ceramic fi ber 
insulation, bolted and tightly sealed to boiler frame.
D. Flame observation port in access door at rear of boiler.
E. Single side access; combustion chamber, tubes and burner 
head are completely accessible from one side simplifying 
maintenance and minimizing fl oor space.
F. Minimum sized fl ue vent. 
G. Control panel: all controls installed with connections to 
terminal strip. 
H. Forced draft, fl ame retention head type burner. Effi cient 
combustion of oil or gas, plus quiet operation. 
I.  Heavy steel boiler frame, built and stamped in accordance 
with the appropriate ASME Boiler Code.
J. Heavy gauge steel boiler jacket with rust-resistant zinc 
coating and enamel fi nish, insulated with 1½" fi berglass to 
ensure exceptionally cool outer surface.
E
F
G
H
K
J
A
D
L
M
I
Bryan AB Series Boiler Specifi cations
 
   AB90-W 
900 (264) 
720 (211) 
  21 (211) 
752 (220) 
22 (220) 
— 
113 (10.5) 
2,000 (907)
 
AB90-S 
900 (264) 
720 (211) 
  21 (211) 
— 
— 
742  (337) 
113 (10.5) 
2,600 (1,179)
    AB120-W  1,200 (352) 
960 (281) 
  29 (281) 
1,002 (294) 
30 (294) 
— 
148 (13.8) 
2,250 (1,021)
   AB120-S 
1,200 (352) 
960 (281) 
  29 (281) 
— 
— 
990  (449) 
148 (13.8) 
3,050 (1,384)
    AB150-W  1,500 (440) 
1,200 (352) 
  36 (352) 
1,253 (367) 
37 (367) 
— 
184 (17.1) 
2,550 (1,157)
   AB150-S 
1,500 (440) 
1,200 (352) 
  36 (352) 
— 
— 
1,237   (561) 
184 (17.1) 
3,500 (1,588)
    AB200-W  2,000 (586) 
1,600 (469) 
  48 (469) 
1,670 (489) 
50 (489) 
— 
244 (22.7) 
3,050 (1,384)
   AB200-S 
2,000 (586) 
1,600 (469) 
  48 (469) 
— 
— 
1,649  (748) 
244 (22.7) 
4,150 (1,882)
    AB250-W  2,500 (733) 
2,000 (586) 
  60 (586) 
2,088 (612) 
62 (612) 
— 
303 (28.2) 
3,500 (1,588)
   AB250-S 
2,500 (733) 
2,000 (586) 
  60 (586) 
— 
— 
2,062  (935) 
303 (28.2) 
4,800 (2,177)
    AB300-W  3,000 (879) 
2,400 (703) 
  72 (703) 
2,505 (734) 
75 (734) 
— 
350 (32.5) 
3,750 (1,701)
   AB300-S 
3,000 (879) 
2,400 (703) 
  72 (703) 
— 
— 
2,474  (1,122) 
350 (32.5) 
5,100 (2,313)
BOILER
MODEL
(1)
INPUT
MBH 
(KW)
OUTPUT@ 80% 
EFFICIENCY
(2)
MBH (KW)
HP (KW)
OUTPUT@ 83.5% 
EFFICIENCY
(3)
MBH (KW)
HP (KW)
STEAM OUTPUT
(4)
LBS/HR (KG/HR)
HEATING 
SURFACE
SQ. FT. (M
2
)
APPROX. 
SHIP 
LBS. (KG)
NOTES:    
(1) W = Water / S = Steam  
 
 
(2) Output and horsepower based on boiler industry standard of 80% of input. 
 
 
(3) Output and horsepower based on an average natural gas combustion effi ciency of 83.5% for hot water boiler. Actual combustion effi ciencies for oil will be higher.
 
 
(4) Lbs. steam per hour from and at 212°F.
B