 CLASSIC C33-3 Freestanding Gas Stove
PILOT ADJUSTMENT
Periodically check the pilot fl ames. Correct 
fl ame pattern has three strong blue fl ames: 
1 fl owing around the thermopile, 1 around 
the thermocouple and 1 fl owing across the 
burner (it does not have to be touching the 
burner).
Note:  If you have an incorrect fl ame  pat-
tern, contact your Regency
®
 dealer 
for further instructions.
Incorrect fl ame pattern will have small, prob-
ably yellow fl ames, not coming into proper 
contact with the rear burner or thermopile 
or thermocouple. 
 
Top View of pilot fl ame
Top View of pilot fl ame
MAINTENANCE
GENERAL VENT 
MAINTENANCE
Conduct an inspection of the venting system 
at least annually. Recommended areas to 
inspect are:
1)  Check areas of the Venting System which 
are exposed to the elements for corrosion. 
These will appear as rust spots or streaks, 
and in extreme cases, holes. These com-
ponents should be replaced immediately.
2)  Remove the Cap, and shine a fl ashlight 
down the Vent. Remove any birds nests, 
or other foreign material.
3)  Check for evidence of excessive condensa-
tion, such as water droplets forming in the 
liner, and subsequently dripping out the 
joints, Continuous condensation can cause 
corrosion of caps, pipe, and fi ttings. It may 
be caused by having excessive lateral runs, 
too many elbows, or exterior portions of the 
system being exposed to cold weather.
4)  Inspect joints, to verify that no pipe sections 
or fi ttings have been disturbed, and conse-
quently loosened. Also check mechanical 
supports such as Wall Straps for rigidity.
CAUTION: ANY SAFETY SCREEN 
OR GUARD REMOVED FOR SERV-
ICING AN APPLIANCE MUST BE 
REPLACED PRIOR TO OPERAT-
ING THE APPLIANCE.
CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT 
BE PLACED ON OR NEAR THE 
APPLIANCE.
NEVER OPERATE THE APPLIANCE 
WITHOUT THE GLASS PROPERLY 
SECURED IN PLACE.
THERMOPILE / 
THERMOCOUPLE
1)  Loosen the thermocouple or thermopile with 
a 7/16" wrench at bracket.
2)  Disconnect thermocouple by loosening nut 
from the valve with a 9mm wrench. Discon-
nect thermopile by loosening 2 screws 
marked TP on the valve.
3)  Drop the thermocouple or thermopile down 
from the bracket and pull it out of the unit.
4)  Reinstall the new ones in reverse order.
AERATION 
ADJUSTMENT
The aeration adjustment rod is attached to the 
air shutter on the burner. The air shutter adjust-
ment rod is located under the ashlip on the right 
side. The rod is used to adjust the aeration on 
the burner. This adjustment is performed by the 
installer and is primarily used in installations at 
high elevations. Push the rod in for a yellow 
fl ame, or pull out on the rod for a bluer fl ame. 
Air shutter opening:
 Natural 
Gas 
7/16"
 Propane 
Wide 
open
Caution: Carbon will be produced if air shut-
ter is closed too much.
Note:  Aeration Adjustment should only be 
performed by an authorized Regency
®
 
Installer at the time of installation or 
service.
Closed - Tall Yellow fl ame
Open - Short Blue fl ame