Regency F39-LPG ユーザーズマニュアル

ページ / 31
18
Regency
®
 F39 Room Sealed Freestanding Gas Stove
LOG SET 
INSTALLATION
Read the instructions below carefully and 
refer to the diagrams.  If logs are broken 
do not use the unit until they are replaced. 
Broken logs can  interfere with the pilot 
operation.
The gas log kit contains the following:
a) 02-65  Rear 
Log 
b)  02-56  Middle Left Log 
c)  02-44  Front Left Log 
d) 02-46  Left 
Top 
Log 
e)  02-45  Front Right Log 
f) 02-47 Center 
Log 
g)  02-48  Middle Right Log 
h)    Embers 
 
902-151
i)    Lava 
 
902-154
 
Note:  Install Optional Brick Panels prior to 
installing logs.
Embers
Embers
The "02" refer numbers (i.e. 02-65) are 
molded into the rear of each log.
1)  Carefully remove the logs from the box and 
unwrap them.  The logs are fragile, handle 
with care - do not force into position.
2)  Sprinkle the embers on the left and right 
sides of the fi rebox base. 
INSTALLATION
CONVERSION TO LOWER BTU RATING
THIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS
FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
NG Conversion Kit 730-920  
Contains:
Qty. Part #  Description
1  904-240  Burner Orifi ce #37 (NG)
1  918-034  Decal "Converted to 30,000 Btu"
1 918-033  Instruction Sheet
LPG Conversion Kit 730-922
Contains:
Qty. Part #  Description
1  904-390  Burner Orifi ce #52 (LPG)
1  918-034  Decal "Converted to 30,000 Btu"
1 918-033  Instruction Sheet
Additional Piece (pkg. with unit: 
1  
Log Bracket Restrictor
1)  Shut off the gas supply.
2)  Open the front door.  Carefully remove the 
logs and lava rock.
3)  Remove burner. See diagram below.
Burner Orifi ce
4)  Unscrew the 2 Rear 
Log Pins and move 
to the front hole posi-
tion.
 
5)  Remove Rear Log 
Bracket and slide the 
Log Bracket Restric-
tor between the Rear 
Position the Log Bracket Restrictor between  
the Rear Log Bracket and the burner.
6)  Remove burner orifi ce  with a 1/2" spanner 
and discard.
7)  Reinstall new burner orifi ce (NG stamped 
#37 or LPG stamped #52) and tighten.
8)  Reverse steps 3) and 2).
9)  Adjust Flue restrictor setting: To set the Flue 
restriction as indicated in the diagram, simply 
loosen the screws and push the fl ue restric-
tor plate to the correct position. Tighten the 
screws.
 
 
 Unit Btu/h 
Restrictor 
Opening
 F39 40 
Mj/h 
45mm
  
31 
Mj/h 
35mm
Note: Use a magnetic 
type screwdriver if 
possible.
Log Bracket and the burner, secure with the 
2 screws.
Flue Restrictor set-
ting at High Btu/h
Flue Restrictor set-
ting at Low Btu/h
10) Attach the label  "This unit has been con-
verted to..." on top of the data badge over 
the higher Btu information.
11) Check for gas leaks.
12) Check inlet and outlet pressures.
13) Check operation of fl ame control.  Check for 
proper fl ame appearance on logs.