Regency F38-2 Freestanding Gas Stove
INSTALLATION
CLEARANCES TO 
COMBUSTIBLES
The clearances listed below are MINIMUM 
distances.  Measure the clearance to both the 
appliance and the chimney connector.  (The 
farthest distance is correct if the two clear-
ances do not coincide.) 
For example, if the 
appliance is set as indicated in one of the fi gures 
but the connector is too close, move the stove 
until the correct clearance to the connector is 
obtained.  
This unit can be installed on a solid combustible 
surface like a wood fl oor. This unit can also be 
installed directly on carpeting  or vinyl when 
the bottom pedestal cover plate (provided with 
unit) is installed.
This appliance may be installed only with the 
clearances as shown in the situations pictured.  
Do not combine clearances from one type of 
installation with another in order to achieve 
closer clearances. 
Use the minimum clearances shown in the 
diagrams below for all installations.
Clearances
M i n i m u m   c e i l i n g 
height is 36" / 914 mm 
from top of unit.
If further reduced clear-
ances are needed, ob-
tain requirements for 
construction of a pro-
tected wall from your 
local building authori-
ties and their allowable 
reductions of the listed 
clearances.
A  Side Wall to Unit 
7-1/2" / 190 mm
B  Back Wall to Unit 
6" / 155 mm
E  Side Wall to Unit 
2" / 50 mm
DRAFT DIVERTER
This heater has a draft diverter built in. It must 
not be altered, obstructed, or blocked in any way, 
and the unit must be installed so that the draft 
diverter is in the same atmospheric pressure 
zone as the combustion air inlet to the burner. 
This heater must be properly connected to a 
fl ueing system. This heater is equipped with a 
fl ue safety shutoff system.
WARNING: Operation of this heater when 
not connected to a properly installed and 
maintained fl ueing system or tampering with 
the fl ue safety shutoff system can result in 
carbon monoxide (CO) poisoning and pos-
sible death
.
FLUEING
This heater is a fl ued appliance and must be 
connected to a chimney/fl ue in accordance with 
the installation codes.
Note: 
The rear pedestal cover plate must 
always be fi tted for safety. Electrical 
connections inside.
For your safety this heater is equipped with a 
fl ue safety switch designed to sense incorrect 
fl ueing and react by shutting down the gas sup-
ply. This thermally actuated switch is located 
within the draft diverter and will detect either a 
blocked chimney or backdraft condition where the 
chimney fl ow has reversed. If this switch shuts 
the unit down, it indicates a drafting problem that 
must be identifi ed and rectifi ed without delay 
- the thermally activated switch must  never be 
bypassed or disconnected as a hazardous or 
deadly condition can result.
Reference Dimensions
C  Back Wall to Flue Centerline 10-3/4" / 273 mm
D  Side Wall to Flue Centerline  20-1/2" / 520 mm
F  Side Wall to Flue Centerline  11" / 280 mm
14) This unit can be installed on a solid combus-
tible surface like a wood fl oor as well as on 
carpeting.
INSTALLATION 
CHECKLIST
1)  Check Clearances to Combustibles. Refer to 
the "Clearance to Combustibles" section.
2)  Install flueing. Refer to the "Flueing" 
section.
3)  Make gas connections. Refer to the "Gas 
Connection" section. 
 
Test the pilot. Must be as per diagram in the 
"Pilot Adjustment" section. 
4)  If necessary, convert NG to LPG. Refer to 
the "Conversion from NG to LPG" section
5)  Test Gas Pressure. Refer to the "Gas Pipe 
Pressure Testing" section.
6)  Install log set. Refer to the "Log Set 
Installation" section.
7)  Install Front Door. Refer to the "Front Door 
Installation" section.
8) Test 
for 
fl ue spillage (draft test). Refer to the 
"Test for Flue Spillage" section.
9)  Install Optional Features. Refer to the 
following sections where applicable: 
 
a. Optional Wall Thermostat
 
b. Optional Remote Control
10) Final check. Refer to the "Final Check" 
section.
Before leaving this unit with the customer, the 
installer must ensure that the appliance is fi r-
ing correctly and operation fully explained to 
customer.
This includes:
1)  Clocking the appliance to ensure the correct 
fi ring rate (rate noted on label) after burning 
appliance for 15 minutes.
2)  If required, adjusting the primary air to ensure 
that the fl ame does not carbon. First allow 
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that 
causes sooting or carboning or that results in 
damage is not the responsibility of the manu-
facturer.