Regency F38-LPG2 ユーザーズマニュアル

ページ / 23
Regency F38-2 Freestanding Gas Heater
9
INSTALLATION
AERATION 
ADJUSTMENT
The burner aeration is factory set but may need 
adjusting due to either the local gas supply or 
altitude.
 
F38-2 with 38 mj
F38-NG2 
NG:     Full open
F38-LPG2 
LPG:   6.4 mm open
Caution: Carbon will be produced if the air 
shutter is closed too much.
Note:  Any damage due to carboning re-
sulting from improperly setting the 
aeration controls is NOT covered 
under warranty.
Embers.
Embers
The "02" refer numbers (i.e. 02-65) are 
molded into the rear of each log.
1)  Carefully remove the logs from the box and 
unwrap them.  The logs are fragile, handle 
with care - do not force into position.
2)  Sprinkle the embers on the left and right 
sides of the fi rebox base. 
LOG SET 
INSTALLATION
Read the instructions below carefully and 
refer to the diagrams.  If logs are broken 
do not use the unit until they are replaced. 
Broken logs can  interfere with the pilot 
operation.
The gas log kit contains the following:
a) 02-65  Rear 
Log 
b)  02-56  Middle Left Log 
c)  02-44  Front Left Log 
d) 02-46  Left 
Top 
Log 
e)  02-45  Front Right Log 
f) 02-47 Center 
Log 
g)  02-48  Middle Right Log 
h)    Embers 
 
902-151
i)    Lava 
 
902-154
 
Note:  Install Optional Brick Panels prior to 
installing logs.
C)02-44
Pins on Rear Log Support
A)02-65
B)02-56
3)  Place Rear Log A)02-65 on the two pins on 
the rear log support.
4)  Place the Middle  Left Log B)02-56 on the 
two pins as shown.
 
5)  Place Front Left Log C)02-44 onto the 2 
front pins as shown.