Regency FG39-LPG ユーザーズマニュアル

ページ / 36
18
Regency FG39 FireGenie Freestanding Gas Stove
Installer Notice:
These instructions must be left with
the  appliance.
Minimum  pressure:  Remove  one  of  the
cables connected to the electric modulator.
Keeping the nut (B) blocked, screw in the
screw  (C)  to  increase  the  pressure  and
screw it out to decrease it. Use a screw-
driver 6 x 1 blade.
NOTE: The outlet pressure must be set to
minimum 0.74 kPa.
After  carrying  out  all  adjustments,  block
the setting screws with paint, taking care
not to obstruct the breather orifice of the
pressure.
Put back the modulator plastic cap.
WARNING: To ensure the correct opera-
tion of the modulator it is necessary that the
plastic  cap  (A)  is  returned  to  its  original
location.
23) At  the  end  of  all  setting  and  adjustment
operations, check electrical insulation and
gas leaks.
24) Reverse step 20.
25) Check operation of fan and flame control.
26) Check  for  proper  flame  appearance  and
glow  on  logs.
Cable
Electric
Modulator
22)        Adjusting  the  Outlet  Pressure
       All the adjustments must be carried out
       in the following order:
Remove the modulator plastic cap (A)  using
needle nose pliers.
Maximum pressure: Turn the unit ON to its
highest input rating. Screw in the nut (B) to
increase  the  outlet  pressure  and  screw  it
out to decrease it. Use a 10 mm wrench.
NOTE: The outlet pressure must be set to
maximum 2.65 kPa.
21) Turn  on  the  gas  supply  and  plug  in  the
power  cord.
C
B
A
INSTALLATION