17
Blower/Fan
1)  Remove the two screws from the top of the 
fan housing.
2)  Slide the fan up into the rear heat shield.
3)  After aligning holes, secure the fan to the rear 
heat shield using the two screws removed 
earlier.
CAUTION: The connection cord should not 
be in contact with any hot surfaces. 
Do not route cord under or in front 
of unit.
Read the operating instructions for the fan before 
using. See Page 19.
INSTALLATION
Ground
Fan
Fan
Ground
Green
Neutral
Live
White
Fan
Switch
Manual/
Auto
Switch
Black
Black
High
(Black)
Low
(Red)
Black
Fan Thermodisc
(normally open)
120V AC
60 Hz
Blower/Fan Wiring Diagram
CAUTION:   Label all wires prior to disconnection 
when servicing controls. Wiring errors can cause 
improper and dangerous operation.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three pronged 
(grounding) plug for your protection against shock 
hazard and should be plugged directly into a properly 
grounded three-prong receptacle. Do not cut or remove 
the grounding prong from this plug.