Regency F2400M ユーザーズマニュアル

ページ / 28
Regency Freestanding Woodstove
15
MOBILE HOME INSTALLATION
Once you have properly marked the position of 
your unit and the floor protection as outlined in 
the Residential Installation items #1 through #8, 
a supply of fresh air has to be supplied to your 
unit. Cut a minimum 4" (102mm) diameter hole 
through your floor protector and the floor directly 
under your pedestal base to the outside.  Use 4" 
(102mm) duct pipe with a mesh grill to pipe fresh 
air into the pedestal area. Block off the hole in 
the back of the pedestal with the square plate 
and the two 1/2" screws provided.
Place your unit in position and secure it to the 
floor using two lag bolts 3/8" (10mm) x 3-1/2" 
(89mm) through the two holes inside the pedestal 
base. It is important to maintain the structural 
integrity of the Mobile Home floor, walls and roof 
when installing your unit.
For Mobile Home units installed in the U.S. the 
unit must be grounded using a #8 ground wire 
with approved termination and star washer.
In addition to standard installation instructions 
the following requirements are mandatory for 
installation in a mobile home.
1) The  stove  must  be  permanently  bolted  to  
the  floor  of  the  Mobile  Home  using  the  floor 
screws provided.
2) The stove must have a permanent outside 
air source for combustion.
3) The stove must be electrically grounded to 
the steel chassis of the Mobile Home. 
4)  A  listed  double-wall  connector  chimney 
system, roof thimble, spark arrestor and roof 
flashing kit suitable for use in Mobile Homes 
must be used.
5) If the chimney exits the Mobile Home at a 
location other than through the roof, and exits at 
a point 7ft. (2130mm) or less above the ground 
level on which the Mobile Home is positioned a 
guard or method of enclosing the chimney shall 
be fitted at the point of exit for a height up to 
7ft. (2130mm).
6) The  chimney  shall  be  attached  directly  to 
the room heater and shall extend at least 3 ft. 
(914mm)  above  the  part  of  the  roof  through 
which it passes. The top of the chimney should 
project at least 2ft. (610mm) above the highest 
elevation of any part of the Mobile Home within 
10 ft. (3048mm) of the chimney.
7) The chimney system shall comply with Local 
Requirements.
8)  Any  openings  in  a  chimney  guard  where 
required must not permit the entrance of 3/4" 
(19mm) diameter rod.
9) CAUTION: THE STRUCTURAL INTEGRITY 
OF  THE  MOBILE  HOME  ROOF,  FLOOR, 
WALLS  AND  CEILING  MUST  BE  MAIN-
TAINED.
10) Check any other local building code as other 
local codes may apply.
11) WARNING: DO NOT INSTALL IN A SLEEP-
ING ROOM OF A MOBILE HOME.
12) Use silicone to create an effective vapour 
barrier  at  the  location  where  the  chimney  or 
other component penetrates to the exterior of 
the structure.
INSTALLATION
CAUTION:    At  no  time  use  unlabelled 
parts, or substitute parts made for another 
chimney system.
Install  as  per  chimney  manufacturer's 
installation instructions.
WARNING:  Operate  only  with  door  fully 
closed - open feed door to feed fire only.