Regency F2400M ユーザーズマニュアル

ページ / 28
Regency Freestanding Woodstove
16
Slide the tube into the left hand side, as far 
as possible and then bring it back into the 
hole on the right hand side until it locks into 
position.  If the tube will not slide in easily, 
simply use a pair of vise grips or pliers and 
tap it into place with a hammer.  A tighter fit 
will ensure the tube will not move when the 
unit is burning.
2)  Slide the left baffle over the air tubes from 
the front and then push it to the  back. 
SIMPSON DURA-PLUS
Qty.Part # 
Description
1  6DVL8693  Connector Kit
1  6DP-MH9096 Mobile Home Kit
ICC EXCEL 2100 
Qty.Part # 
Description
1  6CL48  
48" Chimney length (also in  
 
 
12", 18", 24" lengths.
1  6RC  
Rain Cap
1  6RCS 
Spark Screen (for rain cap)
1  6RDS/SQS  Round/Square support box
1  6VF 
Flashing
1  6UBA 
"Ultrablack" Close Clearance
 
 
Connector
Canadian Installations*
SECURITY S2100 (see above for details)
ICC EXCEL 2100 (see above for details)
SELKIRK SENTINAL CF
*The use of alternate pitch flashings, support 
box  extensions,  additional  chimney  lengths, 
and additional chimney bracing, may be used 
on each of the previously listed systems.  These 
parts though must be from the same system 
as listed, and must be a similar and/or compli-
mentary part.
CAUTION: At no time use unlabelled 
parts, or substitute parts made for 
another chimney system.
Install as per chimney manufacturer's instal-
lation instructions.
FLUE BAFFLE & 
SECONDARY AIR TUBE 
INSTALLATION
The flue baffle system located in the upper area 
of the firebox is removable to make cleaning 
your chimney system easier.  The baffles must 
be  installed  prior  to  your  first    fire. 
  Smoke 
spillage  and  draft  problems  may  occur  if  
the baffles are improperly positioned.  Check 
the position of the baffles on a regular basis as 
they can be dislodged if too much fuel is forced 
into the firebox.
Freestanding Stove
F2400M
The unit arrives with the  2 baffles on the floor 
of the firebox. 
1)  If all 4 air tubes are installed continue on to 
Step 2), if not, follow the instructions below. 
Install the air tube into the holes in the side 
channels. The notch goes on the right hand 
side with the air holes facing toward the door. 
LISTED COMPONENTS 
FOR MOBILE HOME 
INSTALLATION
The Regency F2400M and S2400M  Freestand-
ing pedestal units are approved for installation 
in a Mobile Home if one of the following pipe 
systems is used. 
U.S. Installation*
METALBESTOS SSII
Qty. Part # 
Description
1  6DS-VK 
Connector Kit
1  6TMH 
Shield/Support
1  6TAF-6 
Flashing
1  6T-36 
Chimney Length
1  6T-18 
Chimney Length
1  6T-CT 
Rain Cap 
PRO-JET 3103
Qty.Part # 
Description
1  PV06-TK  Connector
1  CSB 
Shield/Support
1  RRS 
Radiation Shield
1  LFR03 
Flashing
1  SL3 
Chimney Length
1  SL1 
Chimney Length
1  RCSA 
Rain Cap
SECURITY ASHT
Qty.Part # 
Description
1  DL42A-6 
Connector Kit
1  6SS 
Shield/Support
1  6FAMH 
Flashing
1  6L3 
Chimney Length
1  6L1 
Chimney Length
1  CPE 
Rain Cap
SECURITY S2100
Qty.Part # 
Description
1  DL42A-6 
Connector Kit
1  6XSF 
Support
1  6XFA 
Flashing
1  6XL3 
Chimney Length
1  6XL18 
Chimney Length
1  6XCPE 
Rain Cap
METAL-FAB TEMP/GUARD 2100
Qty.Part # 
Description
1  6DWBK 
Connector
1  6TGRS 
Roof Support
1  6TGG36 
Chimney Length
1  6TGG12 
Chimney Length
1  6TGF 
Flashing
1  6TGC 
Rain Cap
AMERI-TEC HS
Qty.Part # 
Description
1  6DCC 
Connector
1  6HSRS-12  Roof Support 
 
 
(6PLRS-12-BK)
1  6F 
Flashing
1  6HS-36 
Chimney Length
1  6HS-18 
Chimney Length
1  6HS-RCS  Rain Cap (6PL-MPC)
INSTALLATION
3)  Tilt the left baffle up on top of the side chan-
nel and it will leave enough room to position 
the right baffle  in the same manner as Step 
1) above. Then reposition the left baffle flat 
on the air tubes.  
4)  Important: push both baffles so they are 
tight against the side walls. 
Note:  When getting the chimney cleaned, 
push the baffles forward toward the 
front of the stove, this should leave 
sufficient access to the flue.  If it is 
not enough space then remove the 
middle air tube (reverse the procedure 
in step 1) above), and baffle and then 
replace everything when cleaning is 
completed.
Side View
Front View
Front View