CLEARANCES TO COMBUSTIBLES
(Vent-Free  Operation  Only)
Carefully  follow  the  instructions  below.
This  stove  is  a  freestanding  unit
designed  to  set  directly  on  the  floor.
IMPORTANT: 
 You  must  maintain
minimum  wall  and  ceiling  clearances
during  installation. The  minimum
clearances  are  shown  in  Figure  4.
Measure from  outermost  point  of  stove
top.
Minimum Wall and Ceiling Clearances
(see Figure 4)
A.   Clearances   from   outermost   point
of stove top to any combustible side
wall should not be less  than 24
inches.
B.   Clearances  from outermost point of
stove top to any combustible back
wall should not  be less than 10
i n c h e s   ( l n c l u d e s     c o r n e r
installations).
C.   Clearances  from  the  stove top to
the ceiling should not be less than
48 inches.
CONNECTING  TO  GAS
SUPPLY
       
  
 WARNING
:
  
A  qualified  ser-
vice  person  must  connect  heater
to  gas  supply. Follow  all  local
codes.
       
  CAUTION:
    Never      connect
heater  directly  to  the  gas supply.
This  heater  requires an    external
regulator (not  supplied). lnstall  the
external  regulator  between the  heater
and  gas  supply.
INSTALLATION   ITEMS  NEEDED
Before  installing  heater, make  sure
you  have  the  items  listed  below.
 
piping (check  local  codes)
    sealant (resistant to propane/LP gas)
   equipment  shutoff  valve*
   test  gauge  connection*
   sediment  trap
   tee  joint
   pipe  wrench
   flexible gas hose.(check local codes)
*A  CSA  design-certified  equipment
shutoff   valve   with 1/8
 NPT  tap  is
an acceptable  alternative  to  test
gauge  connection. Purchase  the
optional  CSA  design-certified
equipment  shutoff  valve from your
dealer. See  Accessories.
Figure  5 -Gas  Regulator  Location  and  Gas
Line  Access  Into  Stove  Cabinet
Figure  6 -External  Regulator  With
            Vent  Pointing  Down
Figure  7 -Gas  Connection
The  installer  must  supply  an  external regulator.
The  external  regulator  will reduce  incoming  gas
pressure. You must  reduce  incoming  gas  pressure
to  rating
 
 inches  of  water. If you do not reduce
incoming gas pressure, heater regulator damage
could  occur. lnstall external regulator with  the  vent
pointing  down  as  shown in  Figure  6.  Pointing  the
vent  down protects  it  from  freezing  rain  or  sleet.
*   Purchase  the  optional  CSA  design-certified  equipment  shutoff  valve
from  your  dealer. See  
Accessories
.
** Minimum  inlet  pressure  for  purpose  of  input  adjustment.
NG  Models:
5”-10.5” W.C.
Gas supplier provides external regulator for natural gas.
Propane/LP
Supply Tank
purchase