Procom QN300RYLA-W ユーザーズマニュアル

ページ / 25
  1 0
2.   Open  gas supply tank valve.
3.   Make sure control knob of heater is
in the OFF  position.
4.  Check all joints from equipment
shutoff valve to control valve
(LP  GAS  see  Figure  9.1  NATURAL
GAS  see  Figure  9.2).   Apply
mixture of liquid soap and  water
to  gas  joints.  Bubbles forming
show  a  leak.
5.   Correct all leaks at once.
6.  Light heater (see  Operating
Heater). Check all other internal
joints  for  leaks.
7.  Turn  off  heater (see To Turn Off
      Gas  Appliance).
       
  WARNING:
   Failure  to  position
the  parts  in  accordance  with  these
diagrams  or  failure  to  use  only  parts
specifically  approved  with  this  heater
may  result  in  property  damage  or
personal  injury.
       
  CAUTION:
    After  installation
and  periodically  thereafter,  check  to
ensure  that  no  flame  comes  in
contact   with  any  log.  With  the  heater
set  to  High, check  to  see  if  flames
contact  any  log. If  so, reposition  logs
according  to the log  installation
instructions  in  this  manual. Flames
contacting  logs  will  create  soot.
It is very important to install the logs
exactly as instructed. Do not modify
logs. Only use logs supplied with
heater.
Place  log  set  on  grate  to fit  as
illustrated  in  Figure  10.
Make  sure  log  sits  flat  on  firebox
floor (see Figure 10).
IMPORTANT
: Make  sure  log  does
not cover any burner ports (see Fig-
ure 11).
Also,  see  log  placing  instructions.
Figure  10 -Installing    Log  Set
Figure  11 -Installing  Log  Set (Top  View)
Figure  9.2 -Checking Gas Joints
Test  Pressures  Equal  To  or
Less  Than  1/2  PSIG(3.5 kPa
)
1.   Close  equipment  shutoff  valve
(see Figure  8).
2.   Pressurize  supply  piping  system
by  either  using  compressed  air  or
opening  natural  supply  tank
valve.
3.   Check  all  joints  from  gas  meter  to
equipment  shutoff  valve(see
Figure  9). Apply  mixture  of  liquid
soap  and  water  to  gas  joints.
Bubbles  forming  show  a  leak.
4.   Correct  all  leaks  at  once.