Ei Electronics Ei 405 プリント

ページ / 2
 
Shannon Free Zone, Shannon, Co. Clare, Ireland. 
Ph.
+353 61 471277   
Fx.
+353 61 471053   
 
Email.
 eielectronics@eiltd.ie
 
 
Web:
 www.eielectronics.com 
E & OE  As our policy is one of continuous product development, we reserve the right to alter product details without prior notice
.       
Ei405 DataSht RevB
 
 
Model 
Ei405 RF Optical 
 
RF wireless interconnect  
 
Unique house coding feature 
 
Visual RF transmission indicator 
 
High performance optical chamber with integral 
insect screen 
 
Test/Hush button 
 
Advanced suppression and calibration technology 
 
Radio transmitter and receiver in each alarm 
 
Built in auto self test feature 
 
Low power cell warning 
 
Kitemarked to BS EN 14604:2005 
 
5 year guarantee 
 
 
Product Description 
 
The Ei405 is an Optical Smoke Alarm that runs on 9V 
alkaline battery and is part of the RadioLINK range of RF 
alarms.  The RF signal will wirelessly interconnect the 
Ei405 to other RadioLINK products  
 
The Ei405 uses advanced radio transciever technology 
with unique software coding to transmit and receive the 
radio signals.  The transmissions are frequency 
modulated (FM) and use Manchester coding to ensure 
robust signal integrity and avoid signal noise interference 
  
The RF range can be extensively improved by converting 
the alarm into a “repeater” i.e. re-transmission of the RF 
signals. The Ei405 series alarms can be used as a stand 
alone wireless interconnect system or be incorporated 
into existing home security systems 
 
The Ei405 has other advanced features such as high 
performance optical chambers fitted with integral insect 
screens to reduce the chances of false alarms, as well 
as the ability to wireless interconnect up to twelve alarms 
to allow all alarms to sound if just one of the 
interconnected alarms should be triggered. 
 
The Ei405 has built in circuitry to aid suppression of 
voltage transients and RF interference to further reduce 
the chances of false alarms under such conditions 
 
 
 
 
Operation 
 
 
The red indicator will flash every 40 seconds to 
show that the detector has performed an automatic 
self test 
 
 
In normal standby mode the blue indicator will light 
to indicate transmission of an RF signal 
 
 
In code mode, the blue indicator will flash to indicate 
the number of other RF alarms that have been 
“learned” in the system 
 
 
The red indicator will flash rapidly to show an alarm 
condition for the smoke detector 
 
 
The “Test/Hush” button will either silence false 
alarms or perform a unit self test 
 
 
In “Hush” mode the alarm enters a ten minute period 
of reduced sensitivity and the red light flashes every 
10 seconds and then resets 
 
 
When interconnected to other Ei mains powered 
alarms, an alarm on one detector will trigger all other 
interconnected alarms within one second (only the 
triggered alarm will flash a red indicator) 
 
 
The smoke detector will emit a beep and the red 
light flashes every 40 seconds to indicate that the 
battery is depleted and needs to be changed 
 
 
BATTERY POWERED 9V 
RF Communication