Model 
Ei405 RF Optical 
Installation & Placement 
 
 
         
       
 
 
Place the mounting plate on the ceiling/wall and mark the screw holes. Drill 
with a suitable drill bit, insert the screw plugs and screw the plate into position. 
Simply connect the battery on the alarm and slide into position on the 
mounting plate. 
 
The RF alarms should be house coded to prevent possible interference from 
neighbouring installations 
– see instructions for more details. 
 
Alarms should be placed in accordance with the general guidelines shown in 
the diagram above. These recommendations are based on the problem of 
areas of “dead air” close to corners of rooms and apexes of ceilings, which 
could result in the prevention of smoke reaching the smoke detector 
 
 
House Code Procedure 
1.
 
Connect the battery 
2.
 
Hold the house code switch 
(with a small screwdriver) 
until the blue light turns on 
and then release 
3.
 
Similarly, place other alarms 
into house code mode  
4.
 
Check that the number of 
blue flashes (on each alarm) 
corresponds to the number of 
alarms in your system 
5.
 
Remove all alarms from 
house code 
6.
 
Button test each alarm to 
check your system 
 
 
Technical Specification 
 
Sensor  
Optical, uses light scatter from 
smoke 
 
Sensitivity:
 
Complies with BS 5446 Part 1: 
2000 
 
Automatic Self-Test:
  Smoke Chamber is tested every 40 
 
Sec. and unit beeps (without LED 
 
flash) if it is degraded. 
 
Supply Voltage: 
9V alkaline battery 
 
RF Range
1
:
  
150 meters (min) free space 
 
RF Visual Indicator:
 
Blue light flashes continuously for 
1.5 to 3.5 seconds while 
transmitting RF signal 
 
RF Frequency:
 
868.499MHZ (1% duty cycle) 
 
RF Power:
 
+5dBM 
 
Dimensions: 
152mm diameter x 50mm depth
 
 
Weight: 
286g
 
 
 
 
 
 
 
 
 
  
 
Power-On Indicator:
   Red light flashes every 40 seconds 
 
Alarm:  
Electronic Piezoelectric horn 
 
Alarm Sound Output:
  85dB (minimum) at 3m 
 
Alarm Status:
 
Red LED flashes every second on 
 
unit sensing fire 
 
Temperature Range:
  0
0
 to 40
0
 C 
 
Humidity Range:
 
15% to 95% Relative Humidity 
 
Interconnect:
 
Up to 12 RadioLINK products 
 
Plastic material:
 
UL94VO flame retardant 
 
Warranty:
 
5 year (limited) warranty 
 
Approvals:
 
Kitemarked to BS EN 14604: 2005, 
CE Approved
 
 
 
Specifications are subject to change 
1. 
Any obstructions of any sort will result in a reduction in range from 
the free space specification. As such, the actual range will vary 
depending on installation.