Ei Electronics Ei 176 プリント

ページ / 2
 
Shannon Free Zone, Shannon, Co. Clare, Ireland. 
Ph.
+353 61 471277   
Fx.
+353 61 471053   
 
Email.
 eielectronics@eiltd.ie
 
 
Web:
 www.eielectronics.com 
E & OE  As our policy is one of continuous product development, we reserve the right to alter product details without prior notice
.       
Ei176 DataSht RevA
 
  
Model 
Ei 176 Optical 
 
Complete smoke alarm system 
 
Includes high intensity strobe, optical smoke alarm 
and vibration pad 
 
Rechargeable battery back up 
 
Test button 
 
Continuous monitoring of wiring 
 
Interconnectable to other Ei alarms 
 
Auxiliary sockets 
 
Low power cell warning 
 
Complies with BS415:1990 electrical safety 
 
5 year guarantee 
 
 
Product Description 
The Ei176 is a complete smoke alarm system designed 
for the deaf and hard of hearing. The system includes 
the Ei173 control panel, Ei174 vibrating pad and 
Ei105CD optical smoke alarm. 
 
The Ei173 control panel includes a high intensity Xenon 
strobe, a sealed lead-acid rechargeable battery for 
standby use in the event of mains failure and all the 
required circuitry to connect to the Ei105CD smoke 
alarm and Ei174 vibrating pad 
 
The Ei173 control panel also incorporates a Test button 
and circuitry to continuously monitor the system wiring 
 
The Ei174 vibrating pad is designed to be placed under 
the mattress or pillow to waken people who fail to 
respond to the strobe alarm 
 
Up to 11 other smoke/heat alarms (Ei100C/105C/103C) 
can be interconnected to the master smoke alarm 
Ei100CD. The smoke alarms are all powered from the 
control panel and in the event of mains failure the 
rechargeable battery in the panel will power the entire 
system, including the smoke alarms, for one week. 
 
 
 
Operation 
 
The green indicator will illuminate to show mains power 
is present 
 
 
The red indicator will flash once every second to show 
that the mains supply is off and the system is running 
on battery backup power 
 
 
The red indicator will go off as the battery becomes 
depleted (with mains off) 
 
 
The slide switch on the control panel disconnects mains 
and battery power from the control panel and 
extinguishes both LED indicators 
 
 
The “Test” button will check the strobe, vibration pad 
and panel 
 
 
When the Ei105CD optical smoke alarm is activated, 
the Ei173 control panel will flash the strobe at 1Hz and 
activate the vibrating pad 
 
 
The interconnect wiring from the smoke alarm to the 
control panel is monitored so that if the smoke alarm is 
not connected or if it is open/short circuit, then the 
strobe will flash and the vibrating pad will turn on 
 
 
An auxiliary socket allows the connection of an extra 
strobe or vibrating pad 
MAINS POWERED 230V~ 
For the deaf and hard of hearing