Infocus 3534324301 ユーザーズマニュアル

ページ / 67
Manual del usuario de IN3138HD 
 58 —
 
Nº 
Función 
Comando  RW Mín. Máx.
Predeter
minado
Paso 
Parámetro 
16V Color 
Temp 
TMP 
RW  0 
Source 
Specific
Valid only when Display 
Mode = User 
0:Warm 
1:Normal  
2:Cold 
17V Contrast 
CON 
RW  0  100
50 
Valid only when Display 
Mode = User 
18V Current 
Source 
SRC 
RW  0  13
0:VGA1 
1:VGA2 
5:HDMI-1 
7:DP 
12:Video 
13:S-Video 
21V Digital 
Zoom 
DZM 
RW  -10
10
1  -10~10 
27V Error 
Condition 
ERR 
R  n/a
n/a
n/a 
n/a 
0:No error 
1:Lamp not lit after 5 At-
tempts 
3:Lamp went out unexpect-
edly 
4:Fan failure 
5:
 
Overheating 
7: Case open 
8:DMD error 
9:Color wheel 
28V Factory 
Reset 
RST 
W  n/a
1  1:reset 
32V Freeze 
Screen 
FRZ 
RW  0 
1  0:Disable 
34V Gamma 
GTB 
RW  0 
Source 
Specific
Valid only when Display 
Mode = User 
0:1.8  
1:2.0  
2:2.2  
3:2.4 
4:B&W  
5:Linear 
40V Horz. 
Position 
HPS 
RW  -5 
RGB source only 
(HPS?) to get range 
45V 
Lamp Hours in High 
Power Mode 
LMO R 
9999
   
Displays the number of 
hours that the current lamp 
has run in High Power 
(Normal) mode. 
46V 
Lamp Hours in Low 
Power Mode 
LME R 
9999
   
Displays the number of 
hours that the current lamp 
has run in Low Power (Eco) 
mode. 
47V Lamp 
Life 
LIF 
R  n/a
Note
 
 
280W lamp life 
3000 on 
E20.8
 
49V 
Lamp Resets (Total 
number) 
LMR R 
9999
0  1 
 
62V  Lamp Low Power 
IPM 
RW 
0=ECO, 1=Normal