Infocus 3534324301 用户手册
Manual del usuario de IN3138HD
— 58 —
Nº
Función
Comando RW Mín. Máx.
Predeter
minado
Paso
Parámetro
16V Color
Temp
TMP
RW 0
2
Source
Specific
1
Valid only when Display
Mode = User
0:Warm
1:Normal
2:Cold
Mode = User
0:Warm
1:Normal
2:Cold
17V Contrast
CON
RW 0 100
50
1
Valid only when Display
Mode = User
Mode = User
18V Current
Source
SRC
RW 0 13
0
1
0:VGA1
1:VGA2
5:HDMI-1
7:DP
12:Video
13:S-Video
1:VGA2
5:HDMI-1
7:DP
12:Video
13:S-Video
21V Digital
Zoom
DZM
RW -10
10
0
1 -10~10
27V Error
Condition
ERR
R n/a
n/a
n/a
n/a
0:No error
1:Lamp not lit after 5 At-
tempts
3:Lamp went out unexpect-
edly
4:Fan failure
5:
1:Lamp not lit after 5 At-
tempts
3:Lamp went out unexpect-
edly
4:Fan failure
5:
Overheating
7: Case open
8:DMD error
9:Color wheel
8:DMD error
9:Color wheel
28V Factory
Reset
RST
W n/a
1
1
1 1:reset
32V Freeze
Screen
FRZ
RW 0
1
0
1 0:Disable
34V Gamma
GTB
RW 0
5
Source
Specific
1
Valid only when Display
Mode = User
0:1.8
1:2.0
2:2.2
3:2.4
4:B&W
5:Linear
Mode = User
0:1.8
1:2.0
2:2.2
3:2.4
4:B&W
5:Linear
40V Horz.
Position
HPS
RW -5
5
0
1
RGB source only
(HPS?) to get range
(HPS?) to get range
45V
Lamp Hours in High
Power Mode
Power Mode
LMO R
0
9999
Displays the number of
hours that the current lamp
has run in High Power
(Normal) mode.
hours that the current lamp
has run in High Power
(Normal) mode.
46V
Lamp Hours in Low
Power Mode
Power Mode
LME R
0
9999
Displays the number of
hours that the current lamp
has run in Low Power (Eco)
mode.
hours that the current lamp
has run in Low Power (Eco)
mode.
47V Lamp
Life
LIF
R n/a
Note
280W lamp life
3000 on
E20.8
49V
Lamp Resets (Total
number)
number)
LMR R
0
9999
0 1
62V Lamp Low Power
IPM
RW
0
1
0
1
0=ECO, 1=Normal