Please refer back to these guidelines for safe and secure wire connections.
.
Take care not to damage the labels for each wire in handling.
.
Strip insulation 3/8 in. (9.5mm) from wire ends. 
.
Connect labeled wires only to a terminal with corresponding letter.
.
Bend the wire slightly, insert the wire under the contact plate and tighten
    the screw down onto the wire.  
The Wire chart shows wire labels used on 
Ritetemp thermostats. Please determine what 
wires you have and select the correct wiring 
diagram to "go to" on pages 9.
 Before you Connect Wires
What Wires Do You Have?
    9 Wire Connections 
Make sure your wires are labeled.  This is necessary to determine which step-by-step 
wiring diagram you should use. This may require you to find the 'other end' connection for 
each wire on your heating or air conditioning equipment and read the label there. 
If you have a Zoned Heating/Cooling system with multiple thermostats, please refer to our 
website at www.ritetemp-thermostats.com for installation notes or call 1-888-515-2585.
Caution
D o   n o t   a l l o w  
w i r e s   t o   t o u c h  
e a c h   o t h e r   o r   p a r t s   o n   u n i t .  
W i r e s   m u s t   b e   r o u t e d   t h r o u g h  
t h e   h o l e   i n   t h e   b a c k   p l a t e ,   b e l o w  
t h e   t e r m i n a l   b l o c k ,   o r   t h e y   w i l l  
h i t   p a r t s   o n   t h e   c o v e r.  
The Wire Chart below will help you determine the terminal connections you will use 
on your new thermostat. See chart section that applies to your heat/cool system.
OLD THERMOSTAT   NEW THERMOSTAT      DESCRIPTION
R or RH or 4 or V       RH or RC(leave jumper)  Power Wire
                
                     
RH or 4 or V                RH (remove jumper)       Power Heat 
RC or R                       RC (remove jumper)       Power cool
W or H                         W                                    Heat return
Y or M                          Y                                     Cool return (compressor)
G or F                          G                                     Fan return
C or X                          C                                     AC source for thermostat
W2 or H2                     W2                                  2nd stage of heat
Y2                               do not connect                2nd stage of cool (n/a)
W2                               W2                                  Heat pump Aux heat 
E                                                                         Do not connect                 
O (see note below)      O                                    Dmpr/Chg-over (pwr in cool)
B (see note below)      B                                     Dmpr/Chg-over (pwr in heat)
5 or R                          RH                                  Power wire (pwr)
4 or W                         W                                    Turn Valve on
6 or Y or B                   A                                     Turn Valve off
R                                 RH                                   Power wire (pwr)
Y or B                          W                                    Turn Valve off
W                                 A                                     Turn Valve on
O
N
Po
w
er
W
ire
TW
O
Po
w
er
W
ire
s
ZO
N
ED
 
M
O
TO
R
 
VA
LV
ES
ZO
NE
SO
LE
NO
ID
VA
LV
ES
H
EA
T
PU
M
PS
Note: On a heat pump, if O and B are both present, connect O to O and tape off B.