American Water Heater (A)BCG38T500-8P ユーザーズマニュアル

ページ / 40
21
Servicing should only be performed by a Qualifi ed Service Agent
OPERATION AND SERVICE
WHITE RODGERS INTEGRATED CONTROL - THERMOSTAT
Figure 17
WHITE RODGERS IGNITION CONTROL BOARD
Figure 18
Display 
LED Label
Display 
LEDs
To Upper
Temp.
Probe
To Ignition
Control
Board
To Lower
Temp. Probe
Fuse
Pin Number
Label
120 VAC from
Ignition Control
Board
ECO Manual
Reset Button
Temperature
Adjustment
Dial
E3
E1
E4
E2
Diagnostic LED Error 
Flash Codes are 
Displayed Here
120 VAC 
Hot to 
Thermostat
120 VAC Hot 
from On/Off Switch
1
2
3
5
6
4
8
9
7 10
11
12
1
2
3
4
1, 3, 6 -
2 -
7, 10 -
8 -
9, 12 -
From Thermostat
Flame Probe
Blower Prover Switch
Ground
To Gas Valve (24 VAC)
4, 2 -
3, 1 -
To Igniter  (80-120 VAC)
To Blower  (120 VAC) 
120 VAC Neutral 
 to Thermostat 
120 VAC Neutral
from On/Off Switch