Elite Video vsx33 ユーザーズマニュアル

ページ / 112
Additional information
12
93
En
Settings
Professional Calibration EQ graphical output
Video signals are not output 
from the component terminal.
• When a monitor only compatible with resolutions of 480i is connected to the component terminal 
and another monitor is connected to the HDMI terminal, the video signals may not be output to the 
monitor connected to the component terminal. If this happens, do the following:
  – Turn off the power of the monitor connected to the HDMI terminal.
  – Change the VIDEO PARAMETER menu RES setting (page 61).
  – Video signals from the HDMI terminal cannot be output to the component terminals. Input the 
video signals from the player or other source to the composite or component terminals. When using 
the component terminal, assign it at Input Setup.
Symptom
Remedy
The Auto MCACC Setup 
continually shows an error.
• The ambient noise level may be too high. Keep the noise level in the room as low as possible (see 
also Problems when using the Auto MCACC Setup on page 39). If the noise level cannot be kept low 
enough, you will have to set up the surround sound manually (page 82).
• When using only one surround back speaker, connect it to the SURROUND BACK L (Single) 
terminals.
• To use a 5.1-channel speaker set, use the surround speakers for the surround channel, not the 
surround back channel.
• Make sure there are no obstacles between the speakers and the microphone.
• If Reverse Phase is displayed, try the following: 
  – The speaker’s wiring (+ and –) may be inverted. Check the speaker connections.
  – Depending on the type of speakers and their installation conditions, Reverse Phase may be 
displayed even if the speakers are properly connected. If this happens, select GO NEXT and continue.
  – If the speaker is not pointed to the microphone (listening position) or when using speakers that 
affect the phase (dipole speakers, reflective speakers, etc.), it may not be possible to properly identify 
the polarity.
After using the Auto MCACC 
Setup, the speaker size setting 
is incorrect.
• There may have been some low frequency noise in the room from an air-conditioner, motor, etc. 
Switch off all other appliances in the room and use Auto MCACC Setup again.
• Depending on a number of factors (bass reproduction capabilities of the speakers, room size, 
speaker placement, etc.) this may occur in some cases. Change the speaker setting manually in 
Speaker Setting on page 83, and use the 
ALL (Keep SP System) option for the Auto MCACC menu 
in Automatic MCACC (Expert) on page 73 if this is a recurring problem.
Can’t adjust the Fine Speaker 
Distance setting (page 76) 
properly.
• Check that the speakers are all in phase (make sure the positive (+) and negative () terminals are 
matched up properly).
The display shows KEY LOCK ON 
when you try to make settings.
• With the receiver in standby, press 
 STANDBY/ON for about 10 seconds while holding down 
SPEAKERS to disable the key lock.
Most recent settings have been 
erased.
• The power cord was disconnected from the wall while adjusting this setting.
• Settings are only stored if all the zones are turned off. Turn off all the zones before unplugging the 
power cord.
The various system settings are 
not stored.
• Make sure the blue 
 STANDBY/ON light has gone out before unplugging.
Symptom
Remedy
The EQ response displayed in 
the graphical output following 
calibration does not appear 
entirely flat.
• There are cases where the graph does not appear flat (even when selecting ALL CH ADJ in the Auto 
MCACC Setup) due to adjustments made to compensate for room characteristics to achieve optimal 
sound.
• Areas of the graph may appear identical (before and after) when there is little or no adjustment 
needed.
• The graph may appear to have shifted vertically when comparing before and after measurements. 
EQ adjustments made using 
the Manual MCACC setup on 
page 75 do not appear to 
change the graphical output.
• Despite level adjustments being made, the filters used for analysis may not display these 
adjustments in the graphical output. However, these adjustments are taken into account by the 
filters dedicated to overall system calibration.
Symptom
Remedy
VSX-33_UXJCB.book  93 ページ  2010年3月9日 火曜日 午前10時39分