Wiring Connections
1.  Verify that the power has been shut off at the main breaker.
2.  Verify that the dedicated branch circuit for the SubDrive300 is 
equipped with a properly-sized circuit breaker. Refer to Table 2 
(Page 13) for minimum breaker size.
3.  Use the appropriate strain relief or conduit connectors. Type B liquid 
tight fi ttings are recommended for maximum weather protection.
4.  Remove the SubDrive300 lid.
5.  Feed the motor leads through the opening on the bottom right side 
of the unit and connect them to the terminal block positions marked 
GND (Green ground wire), Red, Yellow and Black (Figure 2).
Figure 2: Motor Lead Connections
 WARNING
!
Serious or fatal electrical shock may result from failure to connect 
the motor, the SubDrive300, metal plumbing and all other metal near 
the motor, or cable to the power supply ground terminal, using wire 
no smaller than motor cable wires. To reduce risk of electrical shock,      
disconnect power before working on or around the water system.
Do not use motor in swimming areas.