6.  Feed the 230 VAC power leads through the bottom left side of the 
SubDrive300 controller and connect them to the terminals marked  
L1, L2, and GND (Figure 3).
 
A 10-foot section of pressure sensor cable is provided with the 
controller, but it is possible to use similar 22 AWG wire for distances  
up to 100 feet from the pressure sensor. A 100-foot section of 
pressure sensor cable is available as an accessory.
7.  Feed the pressure sensor leads through the smaller opening located in the 
bottom middle of the SubDrive300 unit and press on the quick  
connect terminals.
8.  Verify that the SubDrive300 unit is properly confi gured for the 
horsepower rating of the motor and pump being used. Please refer to 
the section on Pump Sizing for information on drive confi guration.
9.  Replace the lid. Do not over-tighten the screws.