Panasonic WJ-HD716K ユーザーズマニュアル
50
Time and polarities of the ALARM/CONTROL terminal and the ALARM
terminal
Terminal
Active time
Remarks
Alarm input
100 ms or more
When N.O.: L active
When N.C.: H active
When N.C.: H active
Alarm output
The set time on the setup menu
L active
Alarm reset input
100 ms or more
L active
Emergency recording input
100 ms or more
L active
Available disk space warning
output
output
Duration set for "Buzzer"* starting from the time of the
error occurrence
error occurrence
L active
HDD error output
Duration set for "Buzzer"* starting from the time of the
error occurrence
error occurrence
L active
Camera error output
Duration set for "Buzzer"* starting from the time of the
error occurrence, or until the camera is reset (from the
time of the error occurrence).
error occurrence, or until the camera is reset (from the
time of the error occurrence).
L active
Error output
Duration set for "Buzzer"* starting from the time of the
error occurrence
error occurrence
L active
Time adjustment I/O
Input: 100 ms or more, Output: 1 s
Input/Output: L active
Alarm suspension input
100 ms or more
L active, judged by level
External recording mode
changeover
changeover
100 ms or more
L active, judged by level
Sequence switchover I/O
100 ms or more
L active
Outage detection input
5 s or more
L active
Outage processing end output
10 s or more
H active
* "Buzzer" can be set on the "Basic" page of the setup menu. (+ Page 65)
Note:
• During "L active (Low active)", the logic will be implemented when the voltage level of signal is low.
• During "H active (High active)", the logic will be implemented when the voltage level of signal is high.
• During "H active (High active)", the logic will be implemented when the voltage level of signal is high.