Atlas 240 Series ユーザーズマニュアル

ページ / 8
2
598-1094-04
INSTALLATION
For easy installation, select an existing light with a wall 
switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4 m) 
above the ground. 
NOTE: If fixture is mounted higher than 
8 ft. (2.4 m), aiming the sensor down will reduce coverage 
distance.
For eave mount only:
 Swing the sensor head towards the clamp screw 
joint. 
If  the  sensor  pops  out  of  the  ball  joint,  loosen  the 
clamp screw and push the sensor back into the ball 
joint. Tighten the clamp screw when done.
 Then rotate the sensor head clockwise 180° so the 
controls face down.
Controls
Wall Mount
Eave Mount
For under eave installation, the sensor head must
be rotated
 as shown in the next two steps for proper 
operation and to avoid the risk of electrical shock.
Controls
Controls
Clamp Screw
Dual Light Level Timer
Light comes on half bright for selected time after dusk 
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables 
this feature. The motion sensing features will continue 
to work as described in this manual. If motion is sensed, 
the light turns on full bright for the ON-TIME (1, 5, or 
20 minutes) then returns to dim mode.
Move ON-TIME Switch to 
1, 5, or 20 minutes
Mode Switching Summary
Flip light switch off 
for one second then 
back on*
MANUAL MODE
AUTO
TEST
*  If you get confused while switching modes, turn the 
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.