Listen Technologies CU 6005 ユーザーズマニュアル

ページ / 39
Danish Interpretation Systems 
 
User Manual 
 
Manual 01 18 04438
 
27 
DC 6990P Conference Units – CU 6010/6011 
The following table shows the maximum number of 
units,  which  can  be  connected  to  each  of  the  four 
outputs 
(A1,  A2,  B1  or  B2) 
on  a  CU  6010/6011 
Central  Unit  or  on  each  output  on  an  EX  6010 
Extension Unit or on the output of a PS 6000. 
 
Length of Feeding Cable 
Type CAT5 AWG24  
Length of inter connecting 
Cable, Type CAT5 AWG24  
Total cable length 
Max. number of  
DC 6990P pr output 
10 m 
1 m 
35 m 
26 
30 m 
1 m 
53 m 
24 
50 m 
1 m 
70 m 
21 
100 m 
1 m 
112 m 
13 
150 m 
1 m 
158 m 
10 m 
2 m 
56 m 
25 
30 m 
2 m 
72 m 
22 
50 m 
2 m 
90 m 
19 
100 m 
2 m 
124 m 
13 
150 m 
2 m 
166 m 
 
DC 6990P Conference Units – CU 6005 
The following table shows the maximum number of 
units,  which  can  be  connected  to  the  two  outputs 
(A1 and A2) simultaneously on a CU 6005 in total  
If  only  one  chain  is  used  the  information  in  the 
above table must be used.    
 
Length of Feeding Cable 
Type CAT5 AWG24  
Length of inter connecting 
Cable, Type CAT5 AWG24  
Total cable length 
Max. number of  
DC 6990 for both outputs 
10 m 
1 m 
2x34 m 
2x15 
30 m 
1 m 
2x43 m 
2x14 
50 m 
1 m 
2x62 m 
2x13 
100 m 
1 m 
2x110 m 
2x11 
150 m 
1 m 
2x158 m 
2x9 
10 m 
2 m 
2x36 m 
2x14 
30 m 
2 m 
2x54 m 
2x13 
50 m 
2 m 
2x90 m 
2x12 
100 m 
2 m 
2x118 m 
2x10 
150 m 
2 m 
2x164 m 
2x8