Listen Technologies CU 6005 ユーザーズマニュアル
Danish Interpretation Systems
User Manual
Manual 01 18 04438
29
IS 6132P w/JB 6004 and LS 6032 – CU 6010/6011
Length of Feeding Cable,
Type CAT5 AWG24
Length of cable
between booths
between booths
Number of
booths
Number of
IS 6132/ booths
Number of
LS 6032/ booths
10 m
5 m
19
4
0
10 m
5 m
12
4
4
30 m
5 m
17
4
0
30 m
5 m
10
4
4
50 m
5 m
15
4
0
50 m
5 m
9
4
4
100 m
5 m
11
4
0
100 m
5 m
7
4
4
150 m
5 m
8
4
0
150 m
5 m
5
4
4
CS 6032F Channel Selector w/back light on – CU 6010/6011
The tables below shows the maximum number of
CS 6032F Channel Selectors, which can be
connected to each of the four outputs
CS 6032F Channel Selectors, which can be
connected to each of the four outputs
(A1, A2, B1 or
B2)
on a CU 6010/6011 Central Unit or on each
output on an EX 6010 Extension Unit or on the
output of a PS 6000.
output of a PS 6000.
Length of Feeding Cable
Type CAT5 AWG24
Length of Inter-connecting
cable, Type CAT5 AWG24
cable, Type CAT5 AWG24
Total cable length Max. number of CS 6032 pr
output
30 m
1 m
139 m
110
50 m
1 m
144 m
95
100 m
1 m
184 m
85
150 m
1 m
200 m
51
10 m
2 m
200 m
96
30 m
2 m
200 m
86
50 m
2 m
200 m
76
100 m
2 m
200 m
51
150 m
2 m
200 m
26