Listen Technologies CU 6010 ユーザーズマニュアル

ページ / 39
Danish Interpretation Systems 
 
User Manual 
 
Manual 01 18 04438
 
28
MU 6040C/D and MU 6042D without connected loudspeaker – CU 6010/6011   
This  table  shows  the  maximum  number  of  MU 
6040 Microphone Units, which can be connected  to 
each of the four outputs 
(A1, A2, B1 or B2) 
on a CU 
6010/6011 Central Unit or on each output on an EX 
6010 Extension Unit or on the output of a PS 6000. 
The numbers are valid with no audio in loudspeaker 
(no  loudspeaker  connected  to  each  unit).  If 
loudspeakers  are  used,  then  use  the  figures  for 
CM/DM 60x0P above. 
 
Length of Feeding Cable, 
Type CAT5 AWG24 
Cable length between 
each MU 6040 
Total cable length 
Max. number of  
MU 6040
 
10 m 
2 m 
168 m 
80 
30 m 
2 m 
178 m 
75 
50 m 
2 m 
188 m 
70 
100 m 
2 m 
200 m  
51  
150 m 
2 m 
 200 m  
26  
100 m 
1 m 
151 m  
52 
150 m 
1 m 
 191 m  
42 
IS 6132P Interpreter Units – CU 6010/6011
The tables below shows the maximum number of IS 
6132P Interpreter Sets, which can be connected  to 
each of the four outputs 
(A1, A2, B1 or B2) 
on a CU 
6010/6011 Central Unit or on each output on an EX 
6010 Extension Unit or on the output of a PS 6000. 
The  numbers  are  with no audio in loudspeaker  (no 
loudspeaker connected to each unit).  
If  loudspeakers  are  used,  then  use  the  figures  for 
CM/DM 60x0P above.  
Note:  The  number  of  units  is  dependant  of  how 
many  interpreter  sets  there  are  per  booth  (or 
language), as there only can be one set switched ON 
per language (channel). 
Length of Feeding Cable, 
    Type CAT5 AWG24
  
Length of inter-connecting Cables, 
Type CAT5 AWG24
  
Max. number of units  pr output  
All ON ½ ON 1/3 ON
 
10m 
2  m 
54       x         x 
30m 
2  m 
49       57      60 
50m 
2  m 
44       51        x 
100m 
2  m 
35       40        x 
150m 
2  m 
25       30        x