Listen Technologies CU 6010 ユーザーズマニュアル

ページ / 39
Danish Interpretation Systems 
 
User Manual 
 
Manual 01 18 04438
 
26
Length of Feeding Cable, 
Type CAT5 AWG24 
Length of  Cable between each     
JB 6002, Type CAT5 AWG24 
Total cable 
length 
Number of  
JB 6002 
Max. number of  
DM 60x0 
10 m 
3 m 
61 m 
18 
36 
30 m 
3 m 
75 m 
16 
32 
50 m 
3 m 
89 m 
14 
28 
100 m 
3 m 
127 m 
10 
20 
150 m 
3 m 
168 m 
14 
 
CM/DM 6060F/6510F Chairman/Delegate Units – CU 6010/6011    
The following table shows the maximum number of 
units,  which  can  be  connected  to  each  of  the  four 
outputs 
(A1,  A2,  B1  or  B2) 
on  a  CU  6010/6011 
Central  Unit  or  on  each  output  on  an  EX  6010 
Extension Unit or on the output of a PS 6000. 
 
Length of Feeding Cable 
Type CAT5 AWG24  
Length of inter connecting 
Cable, Type CAT5 AWG24  
Total cable length 
Max. number of  
CM/DM 60x0 pr output 
10 m 
1 m 
39 m 
30 
30 m 
1 m 
56 m 
27 
50 m 
1 m 
73 m 
24 
100 m 
1 m 
115 m 
16 
150 m 
1 m 
160 m 
11 
10 m 
2 m 
64 m 
28 
30 m 
2 m 
78 m 
25 
50 m 
2 m 
94 m 
23 
100 m 
2 m 
130 m 
16 
150 m 
2 m 
170 m 
11 
CM/DM 6560F Chairman/Delegate Units – CU 6010/6011 
The following table shows the maximum number of 
units,  which  can  be  connected  to  each  of  the  four 
outputs 
(A1,  A2,  B1  or  B2) 
on  a  CU  6010/6011 
Central  Unit  or  on  each  output  on  an  EX  6010 
Extension Unit or on the output of a PS 6000.    
 
Length of Feeding Cable 
Type CAT5 AWG24  
Length of inter-connecting 
Cable, Type CAT5 AWG24  
Total cable length 
Max. number of CM/DM 
60x0 pr output 
10 m 
1 m 
35 m 
27 
30 m 
1 m 
53 m 
24 
50 m 
1 m 
70 m 
21 
100 m 
1 m 
113 m 
14 
150 m 
1 m 
159 m 
10 
10 m 
2 m 
58 m 
25 
30 m 
2 m 
72 m 
22 
50 m 
2 m 
88 m 
20 
100 m 
2 m 
126 m 
14 
150 m 
2 m 
166 m