Mitsubishi Electronics MR-J2S- CL ユーザーズマニュアル

ページ / 337
5 -  2
5. PARAMETERS
5.1.2 List
POINT
The parameters marked * before their symbols are made valid by
switching power off once and then switching it on again after parameter
setting.
Refer to the corresponding reference items for details of the parameters.
(1) Item list
Class No.
Symbol
Name and Function
Initial value
Unit
Customer
setting
0
*STY
Command system/regenerative brake option selection
0000
1
*FTY
Feeding function selection
0000
2
*OP1
Function selection 1
0002
3
ATU
Auto tuning
0105
4
*CMX
Electronic gear numerator
1
5
*CDV
Electronic gear denominator
1
6
PED
Movement complete output range
100
m
7
PG1
Position loop gain 1
35
rad/s
8
*ZTY
Home position return type
0010
9
ZRF
Home position return speed
500
r/min
10
CRF
Creep speed
10
r/min
11
ZST
Home position shift distance
0
m
12
For manufacturer setting
0
13
JOG
Jog speed
100
r/min
14
*STC
S-pattern acceleration/deceleration time constant
0
ms
15
*SNO
Station number setting
0
station
16
*BPS
Communication baudrate selection, alarm history clear
0000
17
MOD
Analog monitor output
0100
18
*DMD
Status display selection
0000
B
asi
c p
ara
m
et
ers
19
*BLK
Parameter block
0000