Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
4 -  33 
4. SIGNALS AND WIRING 
 
4.8.2 Detailed description of interfaces 
This section provides the details of the I/O signal interfaces (refer to the I/O division in the table) given in 
section 4.5.1. Refer to this section and make connection with the external equipment. 
 
(1) Digital input interface DI-1 
Give a signal with a relay or open collector transistor. Refer to section 4.8.3 for the source input. 
DICOM
V
CES     
1.0V
I
CEO     
100   A
TR
24VDC   10%
5.6k
For transistor
Approx. 5mA
Switch
150mA
Servo amplifier
EMG, 
etc.
 
 
(2) Digital output interface DO-1 
A lamp, relay or photocoupler can be driven. Install a diode (D) for an inductive load, or install an inrush 
current suppressing resistor (R) for a lamp load. (Rated current: 40mA or less, maximum current: 50mA or 
less, inrush current: 100mA or less) A maximum of 2.6V voltage drop occurs in the servo amplifier. 
Refer to section 4.8.3 for the source output. 
If polarity of diode is 
reversed, servo 
amplifier will fail.
Servo amplifier
ALM, 
etc.
Load
DOCOM
24VDC   10%
150mA
(Note)
 
Note. If the voltage drop (maximum of 2.6V) interferes with the relay operation, apply high voltage (up to 
26.4V) from external source.