Mitsubishi Electronics MR-J3 ユーザーズマニュアル

ページ / 668
 
 
16 -  38 
16. INDEXER POSITIONING OPERATION 
 
16.7 Automatic operation mode 
POINT 
 
In the absolute position detection system, the following restriction condition 
applies for the number of gears on machine-side (parameter No.PA06 CMX) 
and servo motor speed (N). 
When CMX   2000, N   3076.7 r/min 
When CMX   2000, N   3276.7–CMX r/min 
When the servo motor is operated at servo motor speed higher than the limit 
value, the absolute position counter warning (AE3) occurs. 
 
16.7.1 What is automatic operation mode? 
(1) Concept of indexer 
Select the station, which is dividing the circumference (360 degrees) of the machine side into up to 255, 
using 8-bit device of the next station selection 1 to 8 (RYnA to RYnE, and RY(n 2)3 to RY(n 2)5), and 
execute positioning. 
Station No.0
Station No.1
Station No.2
Station No.253
Station No.254
 
Set the number of stations in the parameter No.PC46. 
 
(2) Rotation direction 
There are two types of operation methods: Rotation direction specifying indexer, which is to always rotate in 
the fixed direction and execute positioning to a station, and Shortest rotating indexer, which is to 
automatically change the rotation direction for the shortest distance and execute positioning to a station. 
 
 
Rotation direction specifying indexer 
Shortest rotating indexer