Mitsubishi Electronics MR-J3 ユーザーズマニュアル
16 - 37
16. INDEXER POSITIONING OPERATION
(2) Indication list
Indication Status
Description
b # # Waiting for CC-Link
communication
Power of the CC-Link master module was switched on at the condition that the power of
CC-Link master module is OFF.
The CC-Link master module is faulty.
CC-Link master module is OFF.
The CC-Link master module is faulty.
(Note 1) d # # Ready
The servo was switched on after completion of initialization and the servo amplifier is
ready to operate. (This is indicated for 2 seconds.)
ready to operate. (This is indicated for 2 seconds.)
(Note 1) C # # Not ready
The servo amplifier is being initialized or an alarm has occurred.
(Note 2) $ $ $ Ready for operation
Two seconds have passed after the servo amplifier is ready to operate by turning ON the
servo-on (RYn1).
servo-on (RYn1).
(Note 3) A
Alarm Warning
The alarm No./warning No. that occurred is displayed. (Refer to section 16.12.4.)
8 8
8
CPU error
CPU watchdog error has occurred.
(Note 4)
0 0.
b
JOG operation positioning operation programmed operation DO forced output
# #.
d
(Note 1)
# #.
C
(Note 4)
Test operation mode Motor-less operation
Test operation mode Motor-less operation
Note 1. ## denotes any of numerals 00 to 16 and what it means is listed below.
## Description
00
00
Set to the test operation mode.
01
Station number 1
02
Station number 2
03
Station number 3
:
:
:
:
62
Station number 62
63
Station number 63
64
Station number 64
Note 2. $$$ indicates numbers from 0 to 254, and the number indicates the executing station number.
3.
indicates the warning/alarm No.
4. Requires MR Configurator or MR-PRU03 parameter module.