8VLQJWKH*R7R&RPPDQG
If the user is authorized, a keypad in one partition can be used to perform system 
functions in the other partition by using the GOTO command. 
 
•  You must use an Alpha keypad to access another partition. 
 
•  Keypads automatically return to their original partition after 2 minutes with 
no keypad activity. 
 
1.                     +  [
∗] + partition number (0,1,2,3) 
 (Security 
Code)
 
 
 
0 = return to keypad’s original partition. 
 
1 = partition 1; 2 = partition 2; 3 = common zone 
 
The keypad beeps to confirm the partition change. 
Alpha Display: 
 (-7%61)(
6)%(= 83 %61
 
Fixed-Word Display: Green LED lit
 
 
 
2.  The keypad remains in the new partition until 
directed to go to another partition, or until it 
automatically returns to the original partition.  
 
The active partition number is displayed in the upper 
left portion of screen, if the option is programmed. 
Alpha Display: 
 (-7%61)(
6)%(= 83 %61
 
Fixed-Word Display: 
Green LED lit
 
 
0XOWL3DUWLWLRQ$UPLQJ
Some users can be given Multi-Partition arming ability by being assigned to both 
partitions when programming user attributes.  
When attempting to arm multi-partitions: 
 
•  You must use an Alpha keypad. 
 
•  The system arms only if all partitions are “ready to arm.” 
 
•  If any partition is “not ready,” the system does not arm at all. 
 
•  You can use the GOTO command to bypass open zones before arming. 
 
•  If any partition is already armed when global arming is attempted, that 
partition remains in its existing armed state. 
 
                   +  [0] + arm command (see list below) 
 (Security 
Code)
 
 
Multi-Partition Arming Commands 
 
2 = arms all partitions AWAY 
 
3 = arms all partitions STAY 
 
33 = arms all partitions NIGHT-STAY 
 
4 = arms all partitions MAXIMUM 
 
7 = arms all partitions INSTANT 
 
1 = disarms all partitions 