First Alert K5309-5V2 ユーザーズマニュアル

ページ / 64
 
– 35 – 
6FKHGXOLQJ
 
$ERXW6FKHGXOLQJ
The system provides end-user schedules (programmable by master/installer only), 
which can control various types of events.  
• Each schedule causes a defined event to start and stop (when appropriate) at a 
specified time.  
• Schedules can be set to automatically repeat at various intervals. 
• Schedules can be set for random starting, if desired.  
• FA168CPS provides up to 16 user schedules; FA148CP provides up to 4 user schedules. 
 
&UHDWLQJ6FKHGXOHV
1.
                     +  [#] + [6] [4] 
 (Master 
Code)
  
Alpha Displays: 
 (-7%61)(
6)%(= 83 %61
 
 
 
2. 
Enter a 2-digit schedule number from:  
01-16 (FA168CPS) or 01-04 (FA148CP).  
 Press 
[
∗] to continue. 
)28)6 7',)( 23
=59-8
 
 
 
3.  Enter the desired 2-digit event number from the 
following list.  
 
00 = clear the scheduled event 
 
01 = turn a programmed output on or off 
)28)6 ):)28
 
  
(see 
Using Device Commands section for a list of output device numbers used 
in your system) 
 
02 = set a user access schedule for one or more users 
(see Security Codes section for an explanation of access groups) 
 
03 = send a “latch-key” report to a pager if the system is not disarmed by a specified 
time; message sent is “777-7777.” 
 
04 = automatically arm the system in STAY mode at a specified time  
 
05 = automatically arm the system in AWAY mode at a specified time  
 
06 = automatically disarm the system at a specified time 
 
07 = Display the word “REMINDER” at a specified time 
 
(if selected, the keypad will beep every 30 seconds beginning when the word 
“REMINDER” is scheduled to display. To stop the beeps and cancel the 
display once it starts, simply press any key. 
 Press 
[
∗] to continue.
 
 
4.  For event number “01,” enter the output number 
associated with this schedule. 
 
Otherwise, this prompt is skipped. 
 Press 
[
∗] to continue to the “Start” prompt below. 
():-') 291&)6
<<