Siemens CCIC1410 ユーザーズマニュアル

ページ / 96
Installation 
19 
Siemens Building Technologies
 
 
Fire Safety & Security Products 
 
05.2009
 
 
7.1.1 
Internet connection via a router 
 
Before setting up the network camera over the Internet, make sure you have a 
router, and follow the steps below. 
1. 
Connect your network camera behind a router. The Internet environment is 
illustrated as below. For information on how to obtain an IP address, see 
chapter 8.5: Network settings. 
 
 
 
2. 
In this example, the Local Area Network (LAN) IP address of your network 
camera is 192.168.0.3. Please forward the following ports for the network 
camera on the router. 
– 
HTTP port  
– 
RTSP port  
– 
RTP port for audio  
– 
RTCP port for audio  
– 
RTP port for video  
– 
RTCP port for video 
If you have changed the port numbers on the Network page, please open the 
ports accordingly on your router. For information on how to forward ports on 
the router, please refer to the user’s manual of your router. 
3. 
Find out the public IP address of your router provided by your ISP (Internet 
Service Provider). Use the public IP and the secondary HTTP port to access 
the network camera from the Internet (see chapter 9.7.1: Network type).