IBM 8688 ユーザーズマニュアル

ページ / 262
The
 
test
 
routines
 
check
 
all
 
serial
 
port
 
controllers
 
at
 
speeds
 
from
 
300
 
to
 
115,200
 
bps
 
(up
 
to
 
460,800
 
bps
 
if
 
a
 
16550
 
UART
 
is
 
installed).
 
3.
   
Select
 
the
 
number
 
of
 
data
 
bits,
 
number
 
of
 
stop
 
bits,
 
and
 
parity
 
type
 
for
 
the
 
serial
 
port.
 
4.
   
Select
 
a
 
field
 
using
 
the
 
 
and
 
+
 
keys
 
and
 
set
 
the
 
parameters.
 
5.
   
Select
 
Continue,
 
and
 
press
 
Enter.
The
 
serial
 
port
 
tests
 
include
 
the
 
following:
 
v
   
Serial
 
Port
 
Hardware
 
Test
 
The
 
serial
 
port
 
hardware
 
test
 
diagnoses
 
hardware
 
attached
 
to
 
the
 
serial
 
port.
 
v
   
Internal
 
Loopback
 
Test
 
This
 
test
 
verifies
 
the
 
proper
 
functionality
 
of
 
the
 
transmitter
 
and
 
receiver
 
register
 
in
 
the
 
serial
 
port
 
using
 
the
 
internal
 
loopback
 
mechanism.
  
Attention:
  
Running
 
this
 
test
 
with
 
console
 
redirection
 
might
 
slow
 
down
 
the
 
server.
 
v
   
External
 
LoopBack
 
Test
 
This
 
test
 
verifies
 
the
 
proper
 
functionality
 
of
 
the
 
transmitter
 
and
 
receiver
 
register
 
in
 
the
 
serial
 
port.
 
This
 
test
 
requires
 
an
 
external
 
loopback
 
connector
 
to
 
be
 
physically
 
connected
 
to
 
the
 
serial
 
port.
  
Attention:
  
Running
 
this
 
test
 
with
 
console
 
redirection
 
might
 
slow
 
down
 
the
 
server.
 
v
   
FIFO
 
Test
 
This
 
test
 
verifies
 
that
 
the
 
first-in
 
first-out
 
(FIFO)
 
function
 
in
 
the
 
serial
 
port
 
is
 
functioning
 
properly.
 
This
 
test
 
is
 
enabled
 
only
 
for
 
UART
 
16550
 
and
 
above.
 
v
   
Baud
 
Rate
 
Test
 
This
 
test
 
verifies
 
the
 
accuracy
 
of
 
the
 
data
 
being
 
transferred
 
by
 
the
 
serial
 
port
 
at
 
different
 
baud
 
rates.
For
 
the
 
serial
 
port
 
test
 
error
 
codes,
 
see
 
 
 
 
 
 
 
 
 
LED
 
Test
 
Use
 
this
 
test
 
to
 
diagnose
 
all
 
LEDs
 
that
 
can
 
be
 
set
 
using
 
software
 
and
 
visible
 
after
 
the
 
server
 
is
 
assembled.
 
This
 
test
 
lights
 
all
 
LEDs
 
in
 
the
 
server
 
and
 
prompts
 
you
 
to
 
check
 
that
 
they
 
are
 
all
 
lit;
 
then,
 
it
 
turns
 
off
 
all
 
LEDs
 
and
 
prompts
 
you
 
to
 
check
 
that
 
they
 
have
 
been
 
turned
 
off.
 
RXE
 
Port
 
Test
 
Use
 
this
 
test
 
to
 
diagnose
 
problems
 
with
 
the
 
RXE
 
ports.
 
The
 
RXE
 
Port
 
Test
 
consists
 
of
 
the
 
following
 
sub-tests:
 
v
   
RIOG
 
(RXE)
 
Status
 
This
 
test
 
displays
 
the
 
status
 
of
 
the
 
RXE
 
ports
 
and
 
the
 
attached
 
RXE-100
 
units.
 
v
   
RIOG
 
Port
 
A
 
Test
 
This
 
test
 
verifies
 
the
 
quality
 
of
 
the
 
connection
 
from
 
the
 
RXE
 
Expansion
 
Port
 
(A)
 
connector
 
to
 
a
 
remote
 
I/O
 
enclosure.
 
v
   
RIOG
 
Port
 
B
 
Test
 
This
 
test
 
verifies
 
the
 
quality
 
of
 
the
 
connection
 
from
 
the
 
RXE
 
Expansion
 
Port
 
(B)
 
connector
 
to
 
a
 
remote
 
I/O
 
enclosure.
 
v
   
RXE-100
 
Side
 
A
 
Port
 
Test
 
This
 
test
 
verifies
 
the
 
quality
 
of
 
the
 
connection
 
from
 
the
 
RXE-100
 
Side
 
A
 
connector
 
to
 
the
 
RXE
 
Expansion
 
Port.
   
Chapter
 
3.
 
Diagnostics
 
61