DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1126
OPS-LINE (DS1 Off Premises Station Line) 
9
Error Log Entries and Test to Clear Values
Notes:
a. This is a software audit error that does not indicate any hardware 
malfunction. Run the Short Test Sequence and investigate associated 
errors (if any).
b. The DS1 OPS Line has been busied out by a busyout station <ext> 
command. No calls can be made on this line.
c. This error type indicates that the circuit pack has been removed or has 
been insane for more than 11 minutes. To clear the error, reinsert or 
replace the circuit pack.
d. Error Type 1793 indicates a problem with the DS1 Interface circuit pack. 
Since there is no error against the OPS-LINE port, no alarm is raised 
against the OPS-LINE port. However, there should be errors logged 
against the DS1 Interface circuit pack. Look for DS1-BD/UDS1-BD errors 
in the Hardware Error Log and follow the appropriate procedures provided 
in the DS1-BD/UDS1-BD (DS1/UDS1 Interface Circuit Pack) Maintenance 
documentation.
Table 9-448.
DS1 OPS Maintenance Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test station <ext>
15(a)
Any
Audit and Update Test 
(#36)
18(b)
0
busyout station <ext>
WARNING
OFF
release station <ext>
130(c)
None
WARNING
ON
test station <ext>
1281
Conference Circuit Test 
(#7)
MINOR
ON
test station <ext> l r 4
1537
NPE Crosstalk Test (#6)
MINOR
ON
test station <ext> l r 3
1793(d)
test board UUCSS l