3M 250/900 ユーザーズマニュアル

ページ / 8
 
78-0013-6978-0-B
4
2.3  Move the guide funnel forward on the fiber holder 
until it stops; open doors and fiber clamp.
Funnel Door
Bow Start Door
Clamp
Move forward
Guide funnel
2.4  Strip, clean and cleave the fiber to 8 +/- 0.5 mm 
(.32 ± .02 inches) measured from the end of the 
900 µm buffer. Use the cleave length marker on 
the assembly base to verify the length. Refer to the 
notes at the beginning of this section when using 
loose tube or semi-tight buffered fiber.
2.5  With the guide funnel fully forward, lay the fiber 
in the central groove along the length of the fiber 
holder as shown. Position it such that the stripped 
and cleaved portion extends slightly beyond the tip 
of the guide funnel.
If the fiber has a noticeable amount of curvature, 
orient it so the curvature is directed downward 
toward the fiber holder. In the clamp area of the 
fiber holder, place the fiber in the appropriate 
groove depending on whether it is TIGHT 
BUFFER, or SEMI-TIGHT BUFFER (loose tube).
900 µm semi-tight buffer fi ber
900 µm tight buffer fi ber