2.10  While maintaining the fiber bow, firmly press the 
element actuator button to actuate the splice element 
within the connector.
Note:  Never activate a connector without a fi ber in 
it or with a fi ber only partially inserted. Doing so will 
ruin the connector by blocking fi ber from being fully 
inserted.
2.11  OPTIONAL TESTING STEP: If the connector is 
to be tested and potentially reused, this needs to be 
done at this point in the termination process. To do so, 
carefully remove the fiber holder and connector from 
the assembly base by following steps 2.13 through 2.16. 
Use extra care when handling the connector and fiber 
as the 900 µm buffer has not yet been secured. The 
connector may now be tested. If the connector passes 
the test, reinstall it into the receptacle (2.2), reinsert 
the fiber holder into the assembly base being careful to 
avoid damaging the fiber, and proceed with step 2.12.
To remove the connector from the fiber, place it into 
the cap popper cavity on the assembly base oriented as 
shown. Then press down firmly using equal pressure 
at each end of the connector. This action will pop the 
element activation cap upward thereby opening the 
splice element. Separate the fiber and connector, and 
restart the termination process from the beginning.
Cap popper 
cavity
Apply equal 
downward pressure 
2.12  To activate the 900 µm buffer crimp at the rear of the 
connector, press and hold inward on the release lever 
located on the side of the assembly base, and push the 
guide funnel by the ears toward the connector until it 
stops.
Release Lever
Ear
Ear
2.13  Release and lift the fiber clamp and raise the doors to 
release fiber.
2.14  Slide fiber holder from actuation tool.