Maintenance
7
Engage the strut in the holder.
8
Lift of the drive belt. Then pull out the pin.
9
Pull the frame forwards and refit the pin.
10 Grasp the front edge of the cutting unit, pull out and raise 
into the service position.
If the cylindrical bolt, which is now holding the cutting unit is 
removed, the cutting unit can be lifted off.
Restoring from service position
To leave the service position, reverse the procedures set out 
in Placing in the service position. Make sure that the cutting 
unit’s ”lug” (3) enters the loop correctly on the underside of the 
machine, see diagram.
Checking the blades
To achieve the best mowing results it is important that the 
blades are undamaged and well-sharpened.
Check that the blades’ attachment screws are tight.
The blades should be balanced after sharpening.
Damaged blades should be replaced when hitting obstacles 
that result in a breakdown. Let the servicing dealer judge 
whether the blade can be repaired/ground or must be 
discarded.
Removing the BioClip plug
To change a Combi unit from BioClip function to cutting unit 
with rear ejection, remove the BioClip plug located under the 
unit with three screws.
1
Put the unit in the service position, see Placing in the 
service position.
2
Remove the three screws holding the BioClip plug, and 
remove the plug.
3
Tip: Fit three full-thread screws M8x15 mm in the screw 
holes to protect the threads.
4
Replace the unit in normal position.
Fit the BioClip plug in the reverse order.
!
WARNING! Observe caution to avoid 
trapping your hand.
1
2
IMPORTANT INFORMATION Replacing or sharpening the 
blades should be conducted by an authorised service 