Insert the cartridge in the rough.  The locator tab 
on the cartridge goes straight into the notch in the 
rough*.
Turn on the water supplies.  Grasp the stop unit 
portion of the cartridge and turn it. 
If there is a leak around the cartridge, turn the 
supplies off, and remove the cartridge.  Confirm 
that the sealing gasket from the flushing plug was 
removed.  
Reinstall the cartridge. Turn the stop unit.
If the unit continues to leak, contact Hansgrohe 
Customer Service for a replacement cartridge.  
The positioning pin on the back of the cartridge goes straight into the hole in the rough.    
Use the reserved screws to connect the cartridge retainer plate to the rough.  Tighten the 
screws evenly, using a manual screwdriver, in a cross-wise pattern.  Do not overtighten 
the screws.  
English
*NoteThe earlier version of 
the ThermoBalance I rough does 
not have the notch for the locator 
tab.  See page 6 for cartridge 
modification instructions.
Perform the following test to check for damage to the ceramic 
plates inside the stop unit.
Failure to correctly perform this test can result in possible water 
damage.
locator tab
notch
positioning 
pin hole
stop unit