page 22 — gaC-6HZ 60 HZ geNeRaTOR• OpeRaTiON aNd paRTs maNual — Rev. #1 (03/31/10) 
OperatiOn
7.  If the engine has started, slowly return the choke lever  
(Figure 13) to the 
OpeN position. If the engine has not 
started repeat steps 1 through 8.
8.  Before the generator is placed into operation, run the 
engine for 3-5 minutes. Check for abnormal smells, 
fuel leaks, and noises that would associate with lose 
components.
9.  Place idle control switch (Figure 17) in the 
OFF (down) 
position. This will allow the engine speed to run at about 
3600 RPM's.
Figure 17. Idle Control Switch (OFF)
Figure 18. Idle Control switch (ON)
 NOTICE
dO NOT pull the starter rope all the way to the end.
dO NOT release the starter rope after pulling. Allow it 
to rewind as soon as possible..
 NOTICE
Placing  the  idle  control  switch  in  the 
OFF  position 
(Figure 17) allows the  engine to operate at a maximum 
speed of about 3600 RPM's. 
When the idle control switch (Figure 18) is placed in the 
up position (
ON), the generator will run at idle speed 
(2200 RPM's) until a load is applied, at that time the 
engine speed will increase to 3600 RPM's as long as 
a load is being applied. 
When the load is not in use, the engine speed will drop 
back to the idle mode after about 3 seconds.
10.  Place  main  circuit  breaker  (Figure  19)  in  the 
ON 
position.
Figure 19. Main Circuit Breaker (ON)
11.  Place  GFCI  circuit  breaker  (Figure  20)  in  the 
ON 
position.
Figure 20. GFCI Circuit Breaker (ON)
12.  Read voltmeter on front panel of generator (Figure 21) 
and verify that 120 VAC is displayed. Using an external 
voltmeter as shown in Figure 21, verify that 120 VAC 
is  present  at  the  120V  twist-lock  and  GFCI  duplex 
receptacles. .
Figure 21. 120V/GFCI Receptacles