Multiquip GAC6HZ ユーザーズマニュアル

ページ / 84
gaC-6HZ 60 HZ geNeRaTOR • OpeRaTiON aNd paRTs maNual — Rev. #1 (03/31/10) — page 23
OperatiOn/sHutdOwn
13.  Read voltmeter on front panel of generator (Figure 22) 
and verify that 240 VAC is displayed. Using an external 
voltmeter as shown in Figure 20, verify that 240 VAC 
is present at the 240V twist-lock receptacle.
Figure 22. 240V Receptacle
14.  Connecting of loads (power tools, lighting ect.) to the 
generator receptacles can now be done.
stopping the engine (Normal shutdown)
1.  Place  main  circuit  breaker  (Figure  23)  in  the 
OFF 
position.
Figure 23. Main Circuit Breaker (OFF)
 NOTICE
When using a combination of dual receptacles, total 
load  should  not  exceed  the  rated  capacity  of  the 
generator.
2.  Place  GFCI  circuit  breaker  (Figure  24)  in  the 
OFF 
positing.
Figure 24. GFCI Circuit Breaker (OFF)
3.  Place idle control switch (Figure 25) in the 
OFF position.
Figure 25. Idle Control switch (OFF)
4.  Let engine run at idle with no load for 2-3 minutes.
5.  To  shut-down  the  engine,  place  the  generator's 
operation switch (Figure 26) in the 
OFF position).
Figure 26. Operation Switch (OFF)
6.  Place engine fuel valve lever (Figure 27) in the 
OFF 
position.
Figure 27. Engine Fuel Valve Lever (OFF)
7.  Remove all loads from the generator.
emergency shutdown
8.  Place operation switch (Figure 26) in the 
OFF position