Tascam 2488neo ユーザーズマニュアル

ページ / 124
No. Message
Meaning
Action
9
Import file not 
found. Use 
USB OPEN to 
import file. 
 
Press [EXIT].
The file selected (backup file, WAV file for 
import, or SMF) is not available.
Press NO/EXIT, use the USB OPEN function 
to transfer the appropriate file to the FAT parti-
tion and then try importing again.
10
Invalid Fs rate detect-
ed. Check 
your system 
set-up. 
 
Press [EXIT].
Digital audio input mode has been selected, but 
the 2488neo has detected the wrong sampling 
frequency (Fs) for the incoming digital audio to 
be used.
Press NO/EXIT and check the digital audio 
source. The output should be 44.1 kHz (note 
that some players output 48 kHz). A unit with 
varispeed (pitch control) may have varispeed 
turned on, altering the sampling frequency from 
44.1 kHz.
11
Master track is 
too short. Use 
MIXDOWN 
to correct it. 
 
Press [EXIT].
The master track is too short, and therefore 
cannot be checked.
A master track must be at least 4 seconds 
long in order to burn it to a CD. Set the OUT 
point to 00:00:04:00:0 or later, then press the 
MIXDOWN/MASTERING key and record a 
master track using the mixdown function. 
The OUT point can be set by pressing the OUT 
key while holding down the LOCATE key. 
12
MTC slave mode 
selected. 
Cannot do this 
operation now. 
 
Press [EXIT]. 
Since the unit is currently slaved to external 
MIDI timecode, the selected operation cannot 
take place. Operations not possible in MTC 
slave mode include: pitch control and SSA, 
repeat playback, auto-punch operations, jog 
and trim as well as audio CD playback and 
digital audio input.
Press NO/EXIT and use the menu system 
(SYNC/MIDI->SYNC) to select INTERNAL sync.
13
No file for import 
has been found. 
Change CD [YES], 
else press [NO]
No WAV file for import has been discovered on 
the loaded CD.
Press YES/ENTER to change the disc (use an 
ISO9660 formatted disc which contains audio 
data with 44.1 kHz sampling frequency in WAV 
format) or NO to cancel the operation.
14
No free hard 
disk space, Use 
DELETE UNUSED 
to make space. 
 
Press [EXIT].
The hard disk is full, and the current operation 
has failed because it needs hard disk space.
Press NO/EXIT and use one of the 
SONG
 
menu operations such as DELETE UNUSED or 
ERASE to free up some space (these opera-
tions cannot be undone).
15
No LAST REC 
point. Use 
IN-OUT instead. 
 
Press [EXIT].
Can’t use the last recording point for auto 
punch operations, as no recording has been 
done yet.
Press NO/EXIT and set the IN and OUT points 
as the punch positions. Use the RHSL key to 
refine these points if necessary, by rehearsing 
takes without recording.
16
No locate 
markers have 
been set.Use 
INSERT MARK. 
 
Press [EXIT].
Because there are no mark points currently set, 
a location command cannot be performed.
Press NO/EXIT, and use the INSERT key from 
the home screen to add some mark points at 
the appropriate positions.
17
No master track 
found. Use  
MIXDOWN 
to create one. 
 
Press [EXIT].
An audio CD cannot be made because there 
is no song with a master track created by 
mixdown on the currently used partition.
In order to create an audio CD, master tracks 
for each song must be prepared in advance. 
Select a song that you want to master to a 
CD (MENU -> SONG -> LOAD). Then, after 
setting the OUT point in advance, press the 
MIXDOWN/MASTERING key to execute the 
mixdown function and record a master track. 
Moreover, to write multiple songs to a CD 
together using Disc at Once (DAO), follow the 
above procedures in advance for every song to 
be written. 
15 − Appendix
118 
TASCAM  2488neo