6
Key
[C…B]
Indicates the tonic note of the specified scale.
This setting is not valid for Equal TemperamentStretch
and User All Notes Scale.
Random
[0…7]
As this value is increased, a greater variance will be applied 
to the pitch when each note is sounded. Normally you will 
set this to 0. This parameter is used when simulating instru-
ments that have natural instability in pitch, such as tape-
mechanism organs or acoustic instruments.
If a scale other than Equal Temperament is selected, the 
combination of the selected scale and the “Key” setting 
may skew the tuning of the base key (for example 
A=440 Hz). If this occurs, use “Master Tune” (GLOBAL 
1.1–1a) to correct the pitch.
 2.1–1d: UTILITY
☞ “Write Program” (1.1–1c)
For details on how to select the desired utility function, refer 
to “PROG 1.1–1c: UTILITY.”
Copy Oscillator
This function copies oscillator settings to the currently 
selected program.
1
Select “Copy Oscillator” to access the dialog box.
2
In “From,” select the oscillator that you wish to copy and 
the copy source program. You can use the Bank [A]–
[GM] keys to select the bank.
3
In “To,” select the copy destination oscillator.
4
To execute the Copy Oscillator operation, press [F8] 
(“OK”) key. To cancel, press the [F7] (“Cancel”) key.
Swap Oscillator
This command exchanges the settings of oscillators 1 and 2.
1
Select “Swap Oscillator” to access the dialog box.
2
To execute the Swap Oscillator operation, press [F8] 
(“OK”) key. To cancel, press the [F7] (“Cancel”) key.
This can be selected only if “Mode (Oscillator Mode)” 
(2.1–1a) is Double.
2.1–2: OSC1
The multisample(s) (waveform) or drum kit on which the 
program will be based can be selected here for oscillator 1 
and/or oscillator 2.
The internal ROM contains 425 different multisamples (pre-
set multisamples) and 33 drum kits. RAM multisamples can 
be created in Sampling mode if the EXB-SMPL option (sold 
separately) is installed, or you can use multisamples that 
were loaded in using the Media mode.
The following illustration shows a LCD screen where 
“Mode (Oscillator Mode)” (2.1–1a) has been set to Double
If this is set to Single, the OSC2 page parameter will not 
appear and cannot be set.
The following illustration shows the display when “Mode 
(Oscillator Mode)” (2.1–1a) has been set to Drums.
2.1–2a: OSC1 Multisample
Velocity SW L
H
[001...127]
The oscillator 1 High and Low multisamples that you spec-
ify in “High, Low” (2.1–2b) will be switched at the velocity 
value that you specify here. Notes played with a velocity 
stronger than this value will be sounded by the High multi-
sample.
2.1–2b: High, Low
Here you can select a multisample.
You can select different multisamples for High and Low, and 
use velocity to switch between the two multisamples. Start 
Offset, Reverse, and Level can be adjusted independently 
for the High and Low multisamples.
High:
High MS Bank
[ROM, RAM]
High Multisample
[000...424, 000...999]
Specifies the bank and multisample number of the High 
multisample. The multisample you select here will sounded 
by velocities greater than the value of the “Velocity SW 
L
H
” (2.1–2a) parameter. If you do not wish to use velocity 
switching, set the value to 001, and select only the High 
multisample.
ROM: 
Select a preset multisample.
Use “High Multisample” to select from 000–424.
RAM:
 You can use multisamples that you created in Sam-
pling mode, or multisamples that you loaded in the Media 
mode. (Requires the separately sold EXB-SMPL option and/
or the installation of RAM sample data memory.)
Select the “High Multisample” from a range of 000–999.
If sample data RAM is not installed, the program will 
not sound if you select RAM.
2.1–2a
2.1–2b
2.1–2e
2.1–2c
2.1–2d
2.1–2e