Mitsubishi Electronics A800 ユーザーズマニュアル

ページ / 116
Connection of motor with encoder (vector control)
56
Parameter for the encoder (Pr.359, Pr.369)
Parameter settings for the motor under vector control
Pr.
Name
Initial 
value
Setting 
range
Description
359
C141
Encoder rotation 
direction
1
0
Set when using a motor for which 
forward rotation (encoder) is clockwise 
(CW) viewed from the shaft.
Set for the operation at 
120 Hz or less.
100
Set for the operation at a 
frequency higher than 
120 Hz.
1
Set when using a motor for which 
forward rotation (encoder) is 
counterclockwise (CCW) viewed from 
the shaft.
Set for the operation at 
120 Hz or less.
101
Set for the operation at a 
frequency higher than 
120 Hz.
369
C140
Number of encoder 
pulses
1024
0 to 4096
Set the number of encoder pulses output.
Set the number of pulses before it is multiplied by 4.
The above parameters can be set when the FR-A8AP (option) is mounted.
Motor name
Pr.9 
Electronic 
thermal O/L relay
Pr.71 
Applied 
motor
Pr.80 
Motor 
capacity
Pr.81
Number of 
motor poles
Pr.359
Encoder 
rotation 
direction
Pr.369
Number of 
encoder 
pulses
Standard motor
Rated motor current
Motor capacity
Number of 
motor poles
Constant-torque motor
Rated motor current
Motor capacity
Number of 
motor poles

Offline auto tuning is required (Refer to the FR-A800 Instruction Manual (Detailed))

Set this parameter according to the motor.
CW
CCW