Make  sure  air  hose  is  free  of  snags  and  ob-
structions.    Do  not  attach  an  air  hose  or  tool 
to  your  body.    Entangled  or  snarled  hoses  can 
cause  a  loss  of  balance  or  footing  in  addition  to 
unintentional  tool  operation.  Attach  the  hose  to 
the structure to reduce the risk of loss of balance 
if the hose shifts.
Do  not  abuse  the  air  hose.    Protect  all  hoses 
from kinks, restrictions, solvents or sharp ob-
jects.  keep air hose away from heat, oil, sharp 
edges or moving parts. Replace damaged hoses 
immediately.  Damaged hoses can burst or whip 
around work area.
Only  use  hoses  with  a  minimum  rating  of  200 
PSI.  Use of hoses with a high pressure rating re-
duce the risk of injury from a hose bursting.
Firmly grasp hose in hand when installing hos-
es. If hose is not held firmly or correctly installed, 
hose may whip and injure personnel in the oper-
ating area.
Use  care  when  lifting  and  carrying  the  com-
pressor.  Some compressors are too heavy to be 
lifted  by  one  person.    Get  assistance  before  at-
tempting to lift a compressor to reduce the risk of 
injury.
When  moving  or  loading  a  wheeled  compres-
sor  ensure  that  the  compressor  is  always  on 
a level surface.  If the compressor is placed on 
a sloped surface, it may move unexpectedly and 
result in personal injury.
This  product  contains  chemicals,  including 
lead, known to the State of California to cause 
birth  defects  and  other  reproductive  harm.  
Wash hands after using.
TOOl USe AND CAre
Use this compressor and all accessories in ac-
cordance  with  the  instructions.    Compressor 
and accessories must be used for the purpose for 
which they are designed.  Use of the compressor 
for operations other than what is described in this 
manual can result in a hazardous situation.
Use  only  accessories  that  are  recommended 
by  BOSCH  for  your  particular  model.    Acces-
sories that may be recommended for a particular 
model  tool  may  not  be  suitable  on  other  model 
tools and may result in personal injury.
Before  each  use,  inspect  all  fittings,  hoses, 
pipes,  connections  of  the  compressor.    Do 
not  operate  if  any  portion  of  the  compressor 
is  loose,  missing,  damaged,  malfunctioning, 
disconnected  or  altered.    Never  use  a  com-
pressor that appears damaged or is operating 
abnormally. If the compressor appears to be op-
erating  unusually  and/or  making  strange  noises, 
stop  using  it  immediately  and  contact  your  local 
BOSCH service center. There is a risk of bursting 
if the compressor is damaged.
Before each use inspect compressor for signs 
of leaks or damage.  If leaks are found in the 
compressor pump, air tanks or tubing, replace 
compressor immediately.  Never attempt repair 
leaks, weld or make modifications to the air tank 
or other fluid confining parts as there is a risk of 
bursting.
Do not attempt to operate this air compressor 
without first verifying the oil level in the crank-
case.  This  compressor  is  shipped  with  oil  in  the 
crankcase.  Serious  damage  of  the  compressor 
can  result  from  even  momentary  operation  with-
out proper lubrication.
Never  operate  the  compressor  without  the 
safety  valve.    Verify  operation  of  the  safety 
valve  on  a  daily  basis.    Do  not  use  the  safety 
valve  for  complete  tank  drainage.    The  safety 
valve  is  designed  to  relieve  tank  pressure  to  re-
duce the risk of bursting.  
Never  operate  compressor  without  all  guards 
and other safety features in place and perform-
ing intended function.  If maintenance or servic-
ing requires removal of guard or safety feature, be 
sure to replace the guard or safety feature before 
resuming  operation  of  the  compressor.    Replace 
damaged guards or safety features immediately. 
Never  touch  moving  parts.    Do  not  place  any 
part of your body near compressor moving parts.  
Do not reach around guards to reduce the risk of 
injury.
Do not operate compressor without the air fil-
ter.    Filters  prevent  large  particles  from  entering 
the air stream and damaging compressor internal 
components.
Do  not  allow  particulates  such  as  sawdust  to 
fall into crankcase when crankcase is open for 
inspection.  Particulates  in  oil  may  reduce  com-
pressor life.
Do not use a detergent oil in crankcase. Deter-
gent oils will leave deposits on internal compres-
sor  components  reducing  compressor  life  and 
components.
Do not use compressor for unattended opera-
tion.  Always remain in area when compressor is 
operating  and  turn  off  compressor  when  not  in 
use to reduce the risk of fire. 
Never  place  objects  on  top  or  next  to  com-
pressor.  locate compressor at least 12 in. (30 
cm)  away  from  all  obstructions.    Restricting 
any of the compressor’s ventilation openings can 
cause overheating and could cause a fire.
 
Do not operate the compressor with any pow-