IBM 9077 ユーザーズマニュアル

ページ / 342
Configuration of IP-Forwarding Media Cards 
125
super> write
CARD/0 written
super> 
Optical bypass
Optical bypass capability has to be provided externally. The FDDI face plate 
has a six-pin DIN connector to directly attach a single bypass switch.
As shown in Figure 44, two bypass switches can be attached with the an 
Y-cable adapter. The Y-cable is required to reconcile control pin assignments 
between the GRF and the external switch module. Through the Y-cable, an 
optical bypass switch module attaches to a pair of media interface connectors 
on the FDDI card.
A bypass switch allows the GRF to remove itself from the dual ring during a 
failure or maintenance without causing the ring to "wrap" at upstream and 
downstream neighbors. Should a GRF failure occur, the bypass switch 
connects upstream and downstream neighbors on both the primary and 
secondary rings, and allows the GRF node to remove itself from the ring 
gracefully, while still retaining ring continuity.
A node failure without a bypass switch causes the dual ring to "wrap". A 
wrapped ring absorbs the secondary ring into the primary ring and no longer 
has a backup ring.
Figure 44.  Optical Bypass Switch Attachments
Dual homing
Dual homing provides redundant connectivity between an FDDI media card 
and a single ring.
FDDI
media card
Ring 1
Switch Module
Switch Module 2
Switch Module 1
Ring 2
Ring 1
FDDI
media card