IBM 9077 ユーザーズマニュアル

ページ / 342
158
 
IBM 9077 SP Switch Router: Get Connected to the SP Switch
Configuration assumptions:
  • The SP Switch Router Ethernet media card has been installed according 
  • The SP Switch Router Adapter card has been installed according to 
  • The SP Switch Router Adapter card and SP processor node Switch 
adapters are in the same IP subnet.
  • ARP should be enabled on the SP Switch network to provide the most 
flexibility in assigning IP addresses (strongly recommended!).
  • If ARP is disabled on the SP Switch network, the IP addresses assigned to 
the nodes must be determined by the Switch node numbers. Refer to 
PSSP Planning, Volume 2, Control Workstation and Software Environment 
for details.
Configuration:
A RS/6000 model F50 with a PCI Ethernet adapter card is connected to port 1 
of an Ethernet media card in the GRF 1600. The GRF 1600 SP Switch Router 
Adapter card is attached to the SP Switch of SP21, as shown in Figure 53 
and Table 14 on page 159. The netmask for all interfaces is 255.255.255.0.
Figure 53.  SP Switch - Ethernet Connection
Table 14 on page 159 shows the IP addresses used in our configuration.
SP node
SP Sw
it
c
h
SP node
F50
GRF 1600
1
E
ther
net
SP Switch Router
Adapter card 1
SP node