5.  Stored Stroke Limit 
5.7  Precautions 
 
 
 
III-36 
5.7  Precautions 
(1)  If the maximum value and minimum value of the stored stroke limit's prohibited range are set to the same 
value, the following will occur. 
(a)  When the maximum value and minimum value are set to 0, if the outside is the prohibited range, the 
entire range will be prohibited. If the inside is the prohibited range, the entire range will be the 
moveable range. 
(b)  If data other than 0 is set for the maximum value and minimum value, the entire range will be the 
moveable range. 
(2)  The stored stroke limit IC is valid when the axis parameter #2063 is changed. 
If changed during automatic operation, the function will be validated after the smoothing for all axes 
reaches 0. 
(3)  Make sure that the lower limit value of the stored stroke limit IC setting value is "smaller than the upper 
limit value". 
(4)  The axis parameters #2063, #2061 and #2062 can be changed with DDB.